Home > olympia electronics > olympia electronics BS-850-KIT Wireless Programmable WiFi Electronic Chrono Thermostat User Manual
olympia electronics BS-850-KIT Wireless Programmable WiFi Electronic Chrono Thermostat User Manual
The differential value can be set between 12. ANTI-ICE PROTECTION
0.2 °C and 4.0 °C.
The factory default value is 0.2 °C.
If the room temperature in which the
thermostat is installed falls below 5°C, the
G.
(Heat/Cold). HEATING MODE.
unit activates the burner output irrelevant of
The device can control only heating the ON or OFF state of the thermostat to
units (e.g. diesel burners).
H. (Time) HOUR METER.
prevent ice build up. The burner output is
active for as long as the temperature is
In this screen position you can see the total below 5°C.
operation hours of the burner. This value
can not be altered by the keypad but can be 13. CLEANING THE THERMOSTAT
reset if the battery is removed. The To clean the device use a damp cloth to
maximum value is 9.999 hours.
remove any dust or stains from the covers.
I. (Factory settings) SELECTING Do not use any liquid or dissolvers that will
THE FACTORY DEFAULT SETTINGS.
If for any reason there is the need to restore
damage the plastic covers.
the thermostat to its factory default settings 14. SCREEN MESSAGES
then this setting will restore then if you Following you can see a complete list of
MENU
ENTER
select
and press the key
.This screen messages that can be seen by
does not affect the time and date settings.
consecutively pressing the
key:
The factory default setting is
.
=SetTime=Time and date setting.
=Day = Daily program selection.
=Week = Weekly program selection.
=Mode = Operation mode selection.
=Unit =Temperature unit.
=Backlight = Screen illumination.
=LED= Burner output indication LED.
= Time out = Manual temperature
11. CHANGING THE BATTERY
When the screen shows the
symbol
the unit warns the user that the batteries
have limited energy and that they must be
replaced in the next 3 weeks. To replace the
batteries simple remove the cover (Fig. 2)
to expose the battery compartment. time.
Remove the batteries and within 30
= High Temperature Limit = Upper limit
seconds reinsert new ones in order to avoid for manual temperature adjustment.
a reset of the device. Should this happen it = Low Temperature Limit = Lower limit
will require to adjust the time and date for manual temperature adjustment.
again. All other setting remain unaffected.
Avoid replacing the batteries with the
backlight activated, this will immediately relay.
reset the device and the hour meter. Take
care of the battery orientation and insert the
new batteries according to the graphic
representation etched on the plastic base.
The reverse installation will not harm the
=BoilerTime=Active boiler time
= Differential = Differential for burner
=Absent =Absence program.
=Night = Night program.
=Heat = Heat operation mode.
= RF = Wirelless connection setting
=Factory = Factory default settings.
device but it will not permit it to operate.
The battery life time has been design to be
approximately one year. Factors that
influence the battery life are prolong use of
the keyboard with the backlight active,
increased temperature and humidity as well
as battery quality.
MISCELLANEOUS INDICATIONS
=Lock = keyboard lock.
=Unlock = unlock keyboard.
= Save = Save settings to memory.
= User = Manual program
= Degree Celsius = Celsius
temperature unit.
= Degree Fahrenheit = Fahrenheit
temperature unit.
= Program 1 to 10 = Program number
from 1 to 10.
940851000_09_010
Page 8 from 14
| General | Details |
|---|---|
| Name | olympia electronics BS-850-KIT Wireless Programmable WiFi Electronic Chrono Thermostat User Manual |
| Make | olympia electronics |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.27 MB |

olympia electronics BS-830 Digital Electronic Thermostat Instruction Manual