Home > Honeywell > Honeywell TL6120 5-2 Electric Heating Programmable Thermostat User Guide

Honeywell TL6120 5-2 Electric Heating Programmable Thermostat User Guide

TL6120  
User Guide  
5-2 Programmable Thermostat  
Display  
Time and day  
Screen  
Appears when the  
setpoint is displayed  
Appears if the  
thermostat is configured  
for a fan-forced heater  
Up/Down buttons  
Flashes when the  
clock has been reset  
Program button  
Return button  
Mode button  
Heating power  
indicator  
Temperature *  
Appears during  
a power failure  
Period no. in  
automatic mode  
Period no. in  
economy mode  
Day button  
Hour button  
Minute button  
Economy  
mode  
Automatic  
mode  
Manual  
mode  
Pull cover down  
* The thermostat normally displays the actual (measured) temperature.  
To view the set temperature (setpoint), press either of the  
buttons once.  
1.  
The thermostat is preprogrammed with the following schedule:  
Description  
n
Period  
Monday to Friday  
Saturday & Sunday  
The TL6120 thermostat can be used to control an electric heating  
system such as a baseboard heater, a radiant floor, a radiant ceiling,  
a convector, a fan-forced heater, etc.  
Start Time Temperature Start Time Temperature  
1
2
3
4
Wake  
Leave  
Return  
Sleep  
6:00  
8:00  
21°C (70°F)  
16°C (62°F)  
21°C (70°F)  
16°C (62°F)  
6:00  
--  
21°C (70°F)  
--  
--  
2.  
18:00  
22:00  
--  
Clock and Day Setting  
The clock must be set when TIME flashes on the screen.  
o
22:00  
16°C (62°F)  
To temporarily override the current setpoint, set the desired  
temperature using the buttons. The new setpoint will be used  
until the beginning of the next period.  
n Press the  
o Use the  
p Press the  
button to set the day.  
and buttons to set the clock.  
button to exit.  
To modify the schedule:  
3.  
n Press the  
button until AUTO is selected.  
button.  
Automatic (programmable) mode  
p
o Press the  
To use the Automatic mode, press the  
button until  
Each time you press the  
the periods in the following order (from left to right):  
button, the thermostat displays one of  
AUTO is selected (outlined) on the screen. The current  
period number will appear.  
Monday to Friday  
Saturday and Sunday  
In this mode, the thermostat automatically adjust its  
temperature setpoint according to the period of the day  
(wake up, leave for work, return home and sleep).  
MO TU WE TH FR  
SA SU  
1
2
3
4
1
2
3
4
You can program up to 4 periods in a day. You can set 2 different  
programs: one for the weekdays (Monday to Friday) and another one  
for the weekend (Saturday and Sunday).  
p Set the start time for the period using the  
NOTE: To disactivate the period, press the  
and  
buttons.  
button. Instead  
of displaying the start time of the period, the thermostat will dis-  
play --:--. During operation, the thermostat will skip over that  
period.  
q Set the temperature for the period using the  
buttons.  
r Repeat steps 2 to 4 for the remaining periods.  
s Press the  
button to return the thermostat to normal display.  
TL6120  
69-1904EF  
1/16/06  
1/2  
firealarmresources.com  
GeneralDetails
NameHoneywell TL6120 5-2 Electric Heating Programmable Thermostat User Guide
MakeHoneywell
LanguageEnglish
FiletypePDF (Download)
File size0.24 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Honeywell T6 Pro Programmable Thermostat User Manual
Honeywell T6 Pro Programmable Thermostat User Manual
Honeywell D1-528 Direct Thermostat Installation Guide
Honeywell D1-528 Direct Thermostat Installation Guide
Honeywell FocusPRO P200 Programmable Thermostat User Guide
Honeywell FocusPRO P200 Programmable Thermostat User Guide
Honeywell RCHT8610WF Series Smart Thermostat Installation Guide
Honeywell RCHT8610WF Series Smart Thermostat Installation Guide
Honeywell T9 Smart Thermostat Installation Guide
Honeywell T9 Smart Thermostat Installation Guide
Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide
Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide
Honeywell TL116A Thermostat Installation Guide
Honeywell TL116A Thermostat Installation Guide
T10 Pro Smart Thermostat with Redlink Room Sensor
T10 Pro Smart Thermostat with Redlink Room Sensor
Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide
Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide
Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide
Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide

Honeywell TL6120 5-2 Electric Heating Programmable Thermostat User Guide
Get the free PDF manual for the Honeywell TL6120 5-2 Electric Heating Programmable Thermostat User Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Honeywell TL6120 5-2 Electric Heating Programmable Thermostat User Guide Overview

Summary of Contents

  • Page 1: User guide for TL6120 programmable thermostat. The thermostat can control various electric heating systems. It features a display for time, day, and temperature settings. The thermostat is preprogrammed with a schedule for weekdays and weekends. You can program up to four periods in a day. Automatic mode adjusts the temperature setpoint based on the time of day. To temporarily override the setpoint, adjust the temperature using the buttons. The clock must be set when it flashes on the screen. You can set two different programs for weekdays and weekends. To deactivate a period, press the appropriate buttons to skip that time.
  • Page 2: Manual mode allows manual temperature adjustments. In manual mode, modifications to the temperature setpoint must be done manually. The thermostat housing may reach temperatures between 35°C (95°F) and 40°C (104°F). Economy mode is ideal for weekend residences, maintaining an economy level during absence. The economy mode has two periods that should be set for comfortable and economy levels. The warranty covers defects in workmanship or materials for five years from the date of purchase. During a power outage, the thermostat display remains lit for approximately 15 minutes. Settings are saved in memory during a power outage, but the clock must be re-adjusted if the outage exceeds 5 hours. Honeywell's warranty does not cover removal or reinstallation costs. This warranty gives specific legal rights, which may vary from state to state.
  • Page 3: Guide de l’utilisateur Thermostat programmable 5-2 Affichage Apparaît lorsque la température de consigne est affichée. Écran clignote lorsque l’horloge a été ré-initialisé. Le thermostat TL6120 peut servir à commander un appareil de chauffage électrique tel qu’une plinthe chauffante, un plancher chauffant, un plafond radiant, un convecteur, un appareil de chauffage muni d’un ventilateur, etc. Réglage de l’horloge et du jour L’horloge et le jour doivent être réglés lorsque la mention TIME sur l’écran clignote. Pour modifier temporairement la température de consigne, régler la valeur désirée à partir des boutons. Mode automatique (programmable) Pour placer le thermostat en mode automatique, appuyer sur le bouton jusqu’à ce que la mention AUTO soit sélectionnée à l’écran. Dans ce mode, le thermostat change automatiquement de réglage de température selon la période de la journée. On peut programmer jusqu'à 4 réglages par jour, un pour chaque période.
  • Page 4: Mode manuel (fixe) Pour placer le thermostat en mode manuel, appuyer sur le bouton jusqu’à ce que la mention MAN soit sélectionnée à l’écran. Problèmes et solutions Le thermostat est chaud. En fonctionnement normal, le boîtier du thermostat peut atteindre une température entre 35 °C (95 °F) et 40 °C (104 °F). Vérifier si l’autocollant sur l’écran du thermostat a été enlevé. La température affichée est erronée. Vérifier si le thermostat est placé en mode automatique. Mode économie Pour placer le thermostat en mode économie, appuyer sur le bouton jusqu’à ce que la mention ECONO soit sélectionnée à l’écran. Ce mode est idéal pour les résidences de fin de semaine. Fiche technique Alimentation : 240 V c.a., 50/60 Hz Charge minimale : 500 W (2 A résistive seulement) Plage d’affichage : 0 °C à 70 °C (32 °F à 99 °F) Dimensions : 126 x 121 x 33 mm (5,0 x 4,8 x 1,3 pouces) Garantie Honeywell garantit ce produit contre tout vice de fabrication pour cinq ans à partir de la date d'achat. En cas de défectuosité, Honeywell remplacera ou réparera le produit. La présente garantie ne couvre pas les frais de retrait ou de réinstallation. Panne de courant Lors d'une panne de courant, la mention LP s’affiche pendant les 15 premières minutes. Les réglages sont sauvegardés en mémoire. Si la panne dépasse 5 heures, seule l’horloge du thermostat devra être réglée à nouveau.