Home > NEOMITIS > NEOMITIS RTE7D, RTE7BD Wired Digital 7 Day Programmable Room Thermostat Instruction Manual
NEOMITIS RTE7D, RTE7BD Wired Digital 7 Day Programmable Room Thermostat Instruction Manual
secꢁon (see page 2).
- Opꢀmisaꢀon choice
The thermostat is in Auto Mode but programs are not being executed by the boiler:
- Ensure that the thermostat is in good working condiꢁon.
- Change the baꢀeries.
The OPTI COMFORT mode is acꢁvated by default.
1- Move the programing slider to
posiꢁon
.
The thermostat does not control properly.
- Thermostat sensor may be influenced by a source of heat or cold.
- Check that the communicaꢁon works between the thermostat and boiler.
If the problem persists, contact your installer.
TECHNICAL SPECIFICATIONS
- Power supply: 2 alkaline 1.5 V AA (LR6) baꢀeries.
- Baꢀery life: approx. 2 years.
- Relay outputs: 5(2)A
- Rated impulse voltage: 4000V.
- Micro disconnecꢁon: Type 1B.
- Polluꢁon degree: 2.
2- Press and hold
for 5 seconds to
access the seꢂng mode.
OP appears on the display, the set mode
"CONF" and its corresponding icon flash.
- Automaꢁc acꢁon: 100,000 cycles.
- Class II.
Note: It is recommended to replace annually as part of the normal system service and
before leaving the property empty for a prolonged period.
Environment:
- Operaꢁon temperature: 0°C to +40°C.
- Manual temperature seꢂng range: from +5°C to +30°C.
- Storage temperature: from -10°C to +60°C.
- Humidity: 80% at +25°C (without condensaꢁon)
- Protecꢁon raꢁng: IP30.
5 sec
UKCA declaraꢀon of conformity: We, Neomiꢁs Ltd, hereby declare under
our sole responsibility that the products described in these instrucꢁons
comply with statutory instruments 2016 No.1101 (Electrical Equipment
safety Regulaꢁons), ), 2016 No.1091 (Electromagneꢁc Compaꢁbility
Regulaꢁons) , 2012 n°3032 (ROHS) and following designated standards:
- 2016 No.1101 (Safety): EN 60730-1:2011, EN 60730-2-7:2010/
AC:2011, EN 60730-2-9:2010, EN 62311:2008
3- Turn the dial to select the desired mode:
OP CONF = Opꢁmisaꢁon feature acꢁvated for
OPTI COMFORT mode, priority to comfort
OP ECO = Opꢁmisaꢁon feature acꢁvated for
OPTI ECO mode, priority to energy efficiency
OP OFF = Opꢁmisaꢁon feature deacꢁvated
- 2016 No.1091 (EMC): EN 60730-1:2011 / EN 60730-2-7:2010/AC:2011 / EN 60730-2-
9:2010
- 2012 n°3032 (ROHS): EN IEC 63000:2018
Neomiꢁs Ltd: 16 Great Queen Street, Covent Garden, London, WC2B 5AH UNITED
KINGDOM - contactuk@neomiꢁs.com
EU declaraꢀon of conformity: We, Imhotep Creaꢁon, hereby declare
under our sole responsibility that the products described in these
instrucꢁons comply with the provisions of Direcꢁves and harmonized
standards listed below:
- Arꢁcle 3.1a (Safety): EN60730-1:2011/ EN60730-2-7: 2010/EN60730-2-9: 2010/
EN62311:2008
- Arꢁcle 3.1b (EMC): EN60730-1:2011/ EN60730-2-7: 2010/ EN60730-2-9: 2010
- RoHS 2011/65/UE, amended by Direcꢁves 2015/863/UE & 2017/2102/UE : EN IEC
63000:2018
4- Press
to save, exit seꢂng opꢁmisaꢁon feature and go back to the current
Imhotep Creaꢁon: ZI Montplaisir - 258 Rue du champ de courses - 38780 Pont-Evêque -
France - contact@imhotepcreaꢁon.com
mode.
Neomiꢁs Ltd and Imhotep Creaꢁon belong to Axenco Group.
Control class and energy contribuꢀon, according to ERP 2009/125/EC and related
regulaꢀons
TROUBLESHOOTING
Class IV - PID Room Thermostat, for use with on/off heaꢁng devices.
Electronic room thermostat that controls both the cycle ꢁme of the thermostat and the
raꢁo between on and off periods during the same cycle of the heaꢁng device, depending
on the room temperature. PID control reduces the average water temperature, improves
the accuracy of room temperature control and increases system efficiency.
Display disappears on thermostat.
- Check baꢀeries.
- Replace the 2 baꢀeries. Only use alkaline 1.5V AA (LR6) baꢀeries.
Do not use rechargeable baꢂeries.
The heaꢀng does not come on or does not go off.
- Your room thermostat may have been set up close to a source of heat or on a cold
wall – put it in a recommended locaꢁon (see the “Installing” secꢁon on page 1 for
these locaꢁons).
The symbol
, affixed on the product indicates that you must dispose of it at the end
of its useful life at a special recycling point, in accordance with European Direcꢁve WEEE
2012/19/EU. If you are replacing it, you can also return it to the retailer from which you
buy the replacement equipment. Thus, it is not ordinary household waste. Recycling
products enables us to protect the environment and to use less natural resources.
- Check that the communicaꢁon works between the thermostat and the boiler.
You want to change the operaꢀng mode but when you move the mode slider nothing
happens.
- If the lock symbol is being displayed, then the thermostat is locked.
- Unlock the thermostat by following the instrucꢁons for doing so in the "program lock"
NEOMITIS® LIMITED - 16 Great Queen Street, Covent Garden, London, WC2B 5AH UNITED KINGDOM
Registered in England and Wales No: 9543404
Tel: +44 (0) 2071 250 236 - Fax: +44 (0) 2071 250 267 - E-mail: contactuk@neomiꢁs.com
4
| General | Details |
|---|---|
| Name | NEOMITIS RTE7D, RTE7BD Wired Digital 7 Day Programmable Room Thermostat Instruction Manual |
| Make | NEOMITIS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.63 MB |

NEOMITIS RTE7OTA Wired Digital 7 Day Programmable Smart Room Thermostat Instruction Manual

Neomitis RTMA Mechanical Room Thermostat Instruction Manual

NEOMITIS Rtaneoa Wired Analog Room Thermostat Instruction Manual

NEOMITIS PRG7 RF 7 Day Two Channel Programmer with RF Room Thermostat Instruction Manual

NEOMITIS RTE7SD Mains Powered Digital 7 Day Programmable Room Thermostat Instruction Manual

NEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual

NEOMITIS RTE0B Wired Digital Room Thermostat Installation Guide

NEOMITIS RTUa Mechanical Room Thermostat Instruction Manual