Home > NEOMITIS > NEOMITIS RTE7D, RTE7BD Wired Digital 7 Day Programmable Room Thermostat Instruction Manual

NEOMITIS RTE7D, RTE7BD Wired Digital 7 Day Programmable Room Thermostat Instruction Manual

secꢁon (see page 2).  
- Opꢀmisaꢀon choice  
The thermostat is in Auto Mode but programs are not being executed by the boiler:  
- Ensure that the thermostat is in good working condiꢁon.  
- Change the baꢀeries.  
The OPTI COMFORT mode is acꢁvated by default.  
1- Move the programing slider to  
posiꢁon  
.
The thermostat does not control properly.  
- Thermostat sensor may be influenced by a source of heat or cold.  
- Check that the communicaꢁon works between the thermostat and boiler.  
If the problem persists, contact your installer.  
TECHNICAL SPECIFICATIONS  
- Power supply: 2 alkaline 1.5 V AA (LR6) baꢀeries.  
- Baꢀery life: approx. 2 years.  
- Relay outputs: 5(2)A  
- Rated impulse voltage: 4000V.  
- Micro disconnecꢁon: Type 1B.  
- Polluꢁon degree: 2.  
2- Press and hold  
for 5 seconds to  
access the seꢂng mode.  
OP appears on the display, the set mode  
"CONF" and its corresponding icon flash.  
- Automaꢁc acꢁon: 100,000 cycles.  
- Class II.  
Note: It is recommended to replace annually as part of the normal system service and  
before leaving the property empty for a prolonged period.  
Environment:  
- Operaꢁon temperature: 0°C to +40°C.  
- Manual temperature seꢂng range: from +5°C to +30°C.  
- Storage temperature: from -10°C to +60°C.  
- Humidity: 80% at +25°C (without condensaꢁon)  
- Protecꢁon raꢁng: IP30.  
5 sec  
UKCA declaraꢀon of conformity: We, Neomiꢁs Ltd, hereby declare under  
our sole responsibility that the products described in these instrucꢁons  
comply with statutory instruments 2016 No.1101 (Electrical Equipment  
safety Regulaꢁons), ), 2016 No.1091 (Electromagneꢁc Compaꢁbility  
Regulaꢁons) , 2012 n°3032 (ROHS) and following designated standards:  
- 2016 No.1101 (Safety): EN 60730-1:2011, EN 60730-2-7:2010/  
AC:2011, EN 60730-2-9:2010, EN 62311:2008  
3- Turn the dial to select the desired mode:  
OP CONF = Opꢁmisaꢁon feature acꢁvated for  
OPTI COMFORT mode, priority to comfort  
OP ECO = Opꢁmisaꢁon feature acꢁvated for  
OPTI ECO mode, priority to energy efficiency  
OP OFF = Opꢁmisaꢁon feature deacꢁvated  
- 2016 No.1091 (EMC): EN 60730-1:2011 / EN 60730-2-7:2010/AC:2011 / EN 60730-2-  
9:2010  
- 2012 n°3032 (ROHS): EN IEC 63000:2018  
Neomiꢁs Ltd: 16 Great Queen Street, Covent Garden, London, WC2B 5AH UNITED  
KINGDOM - contactuk@neomiꢁs.com  
EU declaraꢀon of conformity: We, Imhotep Creaꢁon, hereby declare  
under our sole responsibility that the products described in these  
instrucꢁons comply with the provisions of Direcꢁves and harmonized  
standards listed below:  
- Arꢁcle 3.1a (Safety): EN60730-1:2011/ EN60730-2-7: 2010/EN60730-2-9: 2010/  
EN62311:2008  
- Arꢁcle 3.1b (EMC): EN60730-1:2011/ EN60730-2-7: 2010/ EN60730-2-9: 2010  
- RoHS 2011/65/UE, amended by Direcꢁves 2015/863/UE & 2017/2102/UE : EN IEC  
63000:2018  
4- Press  
to save, exit seꢂng opꢁmisaꢁon feature and go back to the current  
Imhotep Creaꢁon: ZI Montplaisir - 258 Rue du champ de courses - 38780 Pont-Evêque -  
France - contact@imhotepcreaꢁon.com  
mode.  
Neomiꢁs Ltd and Imhotep Creaꢁon belong to Axenco Group.  
Control class and energy contribuꢀon, according to ERP 2009/125/EC and related  
regulaꢀons  
TROUBLESHOOTING  
Class IV - PID Room Thermostat, for use with on/off heaꢁng devices.  
Electronic room thermostat that controls both the cycle ꢁme of the thermostat and the  
raꢁo between on and off periods during the same cycle of the heaꢁng device, depending  
on the room temperature. PID control reduces the average water temperature, improves  
the accuracy of room temperature control and increases system efficiency.  
Display disappears on thermostat.  
- Check baꢀeries.  
- Replace the 2 baꢀeries. Only use alkaline 1.5V AA (LR6) baꢀeries.  
Do not use rechargeable baꢂeries.  
The heaꢀng does not come on or does not go off.  
- Your room thermostat may have been set up close to a source of heat or on a cold  
wall – put it in a recommended locaꢁon (see the “Installing” secꢁon on page 1 for  
these locaꢁons).  
The symbol  
, affixed on the product indicates that you must dispose of it at the end  
of its useful life at a special recycling point, in accordance with European Direcꢁve WEEE  
2012/19/EU. If you are replacing it, you can also return it to the retailer from which you  
buy the replacement equipment. Thus, it is not ordinary household waste. Recycling  
products enables us to protect the environment and to use less natural resources.  
- Check that the communicaꢁon works between the thermostat and the boiler.  
You want to change the operaꢀng mode but when you move the mode slider nothing  
happens.  
- If the lock symbol is being displayed, then the thermostat is locked.  
- Unlock the thermostat by following the instrucꢁons for doing so in the "program lock"  
NEOMITIS® LIMITED - 16 Great Queen Street, Covent Garden, London, WC2B 5AH UNITED KINGDOM  
Registered in England and Wales No: 9543404  
Tel: +44 (0) 2071 250 236 - Fax: +44 (0) 2071 250 267 - E-mail: contactuk@neomiꢁs.com  
4
GeneralDetails
NameNEOMITIS RTE7D, RTE7BD Wired Digital 7 Day Programmable Room Thermostat Instruction Manual
MakeNEOMITIS
LanguageEnglish
FiletypePDF (Download)
File size2.63 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
NEOMITIS RTE7OTA Wired Digital 7 Day Programmable Smart Room Thermostat Instruction Manual
NEOMITIS RTE7OTA Wired Digital 7 Day Programmable Smart Room Thermostat Instruction Manual
Neomitis RTMA Mechanical Room Thermostat Instruction Manual
Neomitis RTMA Mechanical Room Thermostat Instruction Manual
NEOMITIS Rtaneoa Wired Analog Room Thermostat Instruction Manual
NEOMITIS Rtaneoa Wired Analog Room Thermostat Instruction Manual
NEOMITIS PRG7 RF 7 Day Two Channel Programmer with RF Room Thermostat Instruction Manual
NEOMITIS PRG7 RF 7 Day Two Channel Programmer with RF Room Thermostat Instruction Manual
NEOMITIS RTE7SD Mains Powered Digital 7 Day Programmable Room Thermostat Instruction Manual
NEOMITIS RTE7SD Mains Powered Digital 7 Day Programmable Room Thermostat Instruction Manual
NEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual
NEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual
NEOMITIS RTE0B Wired Digital Room Thermostat Installation Guide
NEOMITIS RTE0B Wired Digital Room Thermostat Installation Guide
NEOMITIS RTUa Mechanical Room Thermostat Instruction Manual
NEOMITIS RTUa Mechanical Room Thermostat Instruction Manual

NEOMITIS RTE7D, RTE7BD Wired Digital 7 Day Programmable Room Thermostat Instruction Manual