1- Press and hold  
for 5 seconds to  
• Program lock  
GO  
access the seꢂng mode.  
Prog  
1
2
3
ON appears on the display.  
The product is unlocked by default, OFF is displayed.  
When program lock funcꢁon is turned on then following funcꢁons will be disabled:  
- Regardless of physical locaꢁon, Program Slider will always remain as per RUN mode  
(except to access Installer seꢂngs).  
- In Mode Slider AUTO posiꢁon: Manual override will not work.  
- In Comfort Slider posiꢁon: mode will remain as per AUTO mode.  
- BOOST funcꢁon is disabled.  
1- Rotate the dial to ON and locked.  
5 sec  
2- Rotate dial to the leſt to select "Off",  
to the right to select "On".  
2- Then save by pressing  
or move  
the Programming slider.  
3- Then save by pressing  
move the  
Programming mode.  
• Select 2 points/TPI  
Prog  
1
2
3
• Set °C/°F temperature  
GO  
Prog  
1
2
3
2 points = ON/OFF regulaꢁon.  
The pre-set temperature is Celsius (°C).  
TPI  
= Proporꢁonal control algorithm.  
1- Rotate the dial to change to degree  
Fahrenheit.  
The pre-set control algorithm is TPI.  
1- Rotate the dial to change to 2 points  
control algorithm.  
2- Then save by pressing  
or move  
the Programming slider.  
2- Then save by pressing  
or move  
the Programming slider.  
• Set calibraꢀon  
GO  
Prog  
1
2
3
Important: This operaꢀon is reserved for professional installers only; any wrong  
changes would result in control anomalies.  
Note regarding the Advanced installer seꢁngs: If MODE slider is moved or no press/  
rotaꢁon for 15 seconds, it will discard changes and exit installer mode.  
Change should only be made if the temperature measured (measured by a reliable ther-  
mometer) is different by at least 1°C compared to the setpoint temperature of the room  
thermostat.  
• Opꢀmisaꢀon feature  
Prog  
1
2
3
The calibraꢁon adjusts the temperature measured by the ambient temperature sensor  
to compensate for a deviaꢁon from + 3°C to - 3°C in increments of 0.5°C.  
IMPORTANT: Before carrying out the calibraꢀon it is recommended to wait for 4h af-  
ter a setpoint temperature modificaꢀon to insure that the ambient temperature is  
stabilized.  
- Overview  
Dual funcꢀon opꢀmisaꢀon , priority to comfort or energy savings, the choice is yours:  
Depending on various parameters: room inerꢁa, ambient temperature, desired tem-  
perature, the thermostat calculates and opꢁmizes the programming for each heaꢁng  
period whether set to Comfort or Savings (Eco):  
The pre-set calibraꢁon value is 0.  
1- Rotate the dial to adjust the calibraꢁon  
- In OPTI ECO mode, the thermostat’s inbuilt algorithm opꢁmises in order to guarantee  
maximum energy savings throughout the ECO programme.  
to the desired value.  
In this mode, a slight drop in the temperature level at the beginning and end of the  
ECO period is allowed to maximize energy savings. The processor within the thermos-  
tat stops the boiler operaꢁon at the opꢁmum ꢁme to slightly reduce the setpoint  
temperature before the end of the occupancy period.  
In this mode, a slight drop in the temperature level at the beginning and end of the  
comfort period is allowed to maximize energy savings.  
- In OPTI COMFORT mode, the thermostat’s inbuilt algorithm opꢁmises in order to gua-  
rantee maximum comfort during the COMFORT programme. The processor within the  
thermostat starts the boiler operaꢁon at the opꢁmum ꢁme to achieve the setpoint  
temperature at the start of the occupancy period.  
2- Then save by pressing  
the Programming slider.  
or move  
In this mode, the priority is given to anꢁcipaꢁng and maintaining the comfort tempe-  
rature during periods of occupancy.  
3
GeneralDetails
NameNEOMITIS RTE7D, RTE7BD Wired Digital 7 Day Programmable Room Thermostat Instruction Manual
MakeNEOMITIS
LanguageEnglish
FiletypePDF (Download)
File size2.63 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
NEOMITIS RTE7OTA Wired Digital 7 Day Programmable Smart Room Thermostat Instruction Manual
NEOMITIS RTE7OTA Wired Digital 7 Day Programmable Smart Room Thermostat Instruction Manual
Neomitis RTMA Mechanical Room Thermostat Instruction Manual
Neomitis RTMA Mechanical Room Thermostat Instruction Manual
NEOMITIS Rtaneoa Wired Analog Room Thermostat Instruction Manual
NEOMITIS Rtaneoa Wired Analog Room Thermostat Instruction Manual
NEOMITIS PRG7 RF 7 Day Two Channel Programmer with RF Room Thermostat Instruction Manual
NEOMITIS PRG7 RF 7 Day Two Channel Programmer with RF Room Thermostat Instruction Manual
NEOMITIS RTE7SD Mains Powered Digital 7 Day Programmable Room Thermostat Instruction Manual
NEOMITIS RTE7SD Mains Powered Digital 7 Day Programmable Room Thermostat Instruction Manual
NEOMITIS RTE0B Wired Digital Room Thermostat Installation Guide
NEOMITIS RTE0B Wired Digital Room Thermostat Installation Guide
NEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual
NEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual
NEOMITIS RTUa Mechanical Room Thermostat Instruction Manual
NEOMITIS RTUa Mechanical Room Thermostat Instruction Manual

NEOMITIS RTE7D, RTE7BD Wired Digital 7 Day Programmable Room Thermostat Instruction Manual