NEOMITIS Rtaneoa Wired Analog Room Thermostat Instruction Manual
INSTALLATION
RTANEOA
INSTALLATION AND OPERATING
Recommended locaꢀons
for your thermostat.
To ensure that your thermos-
tat provides accurate readings
and controls effecꢀvely, it
must be installed approxima-
tely 1.5 m above floor level
on an inside wall, away from
direct sunshine and any other
sources of heat or cold such as
radiators, cold draughts, etc.
INSTRUCTIONS
WIRED ANALOG ROOM
Important: The thermostat
measures the temperature of
the place where it is installed. It does not take into account the temperature differences
that may exist between different locaꢀons in the house if the temperature is not uniform.
THERMOSTAT
MOUNTING OF THE BASE
1- Loosen screw in the base of the unit.
2- Remove the front cover.
TABLE OF CONTENTS
2 ways of mounꢀng the base to a wall:
• On a connecꢀon box
Pack contains........................................................................................................... 1
Overview................................................................................................................. 1
1- Using a screwdriver, push out the deta- 2- Aꢁach the base directly to the back
Installaꢀon .............................................................................................................. 1
Mounꢀng of the base ................................................................................................................. 1
Wiring......................................................................................................................................... 2
Mounꢀng of the front cover ....................................................................................................... 2
chable areas located at the back of the
base, making an openings which wires
can be routed through.
box using 2 screws (the distance
between the aꢁachment points of the
two screws is 60 mm).
Operaꢀng ................................................................................................................ 2
Seꢁng the temperature ............................................................................................................. 2
Frost protecꢀon mode ................................................................................................................ 2
Limit and lock.......................................................................................................... 2
Troubleshooꢀng ...................................................................................................... 3
Technical specificaꢀons ........................................................................................... 3
What is a room thermostat...................................................................................... 3
Detachable
areas
OVERVIEW
• Surface mounꢀng
1- Using pliers, remove the knockout
areas located at the boꢁom of the
base.
2- Repeat the procedure on the knockout
areas on the front side.
Thank you for choosing to purchase our product. The wired
electronic room thermostat is extremely easy to install,
has an innovaꢀve and ergonomic design. It was designed
to make your life easier and help you to save money on
your heaꢀng bills. It directly regulates room temperature
and controls the heaꢀng circuit which is connected to it
which has a voltage of 230V.
PACK CONTAINS
3- Aꢁach the base to the wall with
2 screws (the distance between
the aꢁachment points of the two
screws is 60 mm).
x2
Conduit
x1
x2
x2
Screws
4- Use conduit in order to protect the wires from pulling off.
The conduit must be in contact with the thermostat.
Thermostat
Screw Anchor
1
RTAA NEO ENG CP V04 31 08 2021
| General | Details |
|---|---|
| Name | NEOMITIS Rtaneoa Wired Analog Room Thermostat Instruction Manual |
| Make | NEOMITIS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.9 MB |

Neomitis RTMA Mechanical Room Thermostat Instruction Manual

NEOMITIS RTE7OTA Wired Digital 7 Day Programmable Smart Room Thermostat Instruction Manual

NEOMITIS RTE7D, RTE7BD Wired Digital 7 Day Programmable Room Thermostat Instruction Manual

NEOMITIS PRG7 RF 7 Day Two Channel Programmer with RF Room Thermostat Instruction Manual

NEOMITIS RTE7SD Mains Powered Digital 7 Day Programmable Room Thermostat Instruction Manual

NEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual

NEOMITIS RTE0B Wired Digital Room Thermostat Installation Guide

NEOMITIS RTUa Mechanical Room Thermostat Instruction Manual

NEOMITIS Rtaneoa Wired Analog Room Thermostat Instruction Manual Overview
Summary of Contents
- Page 1: Installation and operating instructions for the thermostat are provided. The thermostat must be installed approximately 1.5 m above floor level on an inside wall, away from direct sunshine and sources of heat or cold. The thermostat measures the temperature of the location where it is installed and does not account for temperature differences in other areas of the house. There are two ways of mounting the base to a wall: on a connection box or surface mounting. The pack contains necessary components for installation. The wired electronic room thermostat is designed for easy installation and aims to help save on heating bills. It directly regulates room temperature and controls the heating circuit connected to it, which operates at 230V. Instructions include loosening screws, removing the front cover, and attaching the base to the wall. Conduit should be used to protect the wires from pulling off and must be in contact with the thermostat. Overview of mounting procedures and troubleshooting is included in the manual.
- Page 2: Wiring All electrical installation work should be carried out by a suitably qualified electrician or other competent person. The desired temperature can be set by turning the dial. The thermostat can be set at any desired temperature between 7°C and 30°C. Important: Please verify that the total start-up load of all actuators connected to the output does not exceed the max. authorized load for the output. Frost protection mode enables you to protect your home against the effects of cold weather by maintaining a minimum temperature of 8°C. To activate frost protection mode, position the cursor opposite the symbol. At the back of the dial, you will find two jumpers which enable you to limit the range of temperatures to which the system can be set. The jumpers are initially set with no limitation effect. If the desired temperature must not drop below 17°C, position a jumper at the relevant temperature point. If the desired temperature must not go above 23°C, position a jumper at the relevant temperature point.
- Page 3: Troubleshooting The thermostat is not working. Check the circuit breaker and the control fuse in the power supply circuit. A room thermostat simply switches the heating system on and off as necessary. It works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting. The temperature is not being regulated properly. Turning a room thermostat to a higher setting will not make the room heat up any faster. Power supply: 230V AC +/-10%, 50 Hz. Manual temperature setting range: from +7°C to +30°C. Room thermostats need a free flow of air to sense the temperature. The symbol indicates that you must dispose of it at a special recycling point, in accordance with European Directive WEEE 2012/19/EU.