Daylight saving time / standard time changeover:  
The thermostat automatically switches the daylight saving time /  
standard time on or off. On 24th March at 23:59, the time is moved  
forwards by an hour. (daylight saving time) On 28th October at 23:59,  
the time is moved backwards by an hour (standard time).  
Conformity information:  
The manufacturer hereby confirms that this device complies with the  
fundamental requirements and the other relevant provisions:  
- Directive 2014/53/EU  
- RoHS Directive 2011/65/EU  
The full declarations of conformity can be found at:  
Technical data:  
2 x 1.5 V AA alkaline batteries  
Power supply  
(not included in the scope of  
delivery)  
Type of communication  
High-frequency power  
Frequency  
One-way communication ASK  
< 10 mW  
433,92 MHz  
Hysteresis  
1 - 5 °C / in 1°C steps  
Number of  
6 temperature changes per day  
temperature changes  
2 automatic programmes with  
a daily and weekly programme  
Automatic programmes  
Minimum  
10 minutes  
programmable time  
Temperature setting incre-  
0.5 °C increments  
ments  
+5 to 39 °C  
Temperature setting  
(Frost protection 3 °C)  
Temperature measurement each 0.1 °C  
Measuring accuracy  
Battery life  
Protection class  
± 0,5 °C  
One heating period  
IP20  
Operating temperature  
0 °C to 40 °C  
Receiver  
Switching capacity  
Germany  
230 V AC / 6.3 ampere 1449 W  
Receiver  
Switching capacity  
Switzerland  
230 V AC / 6.3 ampere 1449 W  
Output  
Relay contact  
as of July 2020  
Open window recognition  
In all programmes  
GeneralDetails