marmony MTC-40 Radio Controlled Room Thermostat Instruction Manual
INSTALLATION
RECEIVER
1. Connect the receiver to the 230 V socket which you intendto use to
connect your marmony infrared heater.
2. Connect the connector plug on your marmony infrared heater to the
receiver socket.
3. That’s it! In the factory settings, both the transmitter and the receiver
are connected to each other (paired). The receiver now waits for
commands from the transmitter / thermostat.
Manual connection (pairing) of the transmitter and receiver:
If you wish to connect an additional receiver to your radio-controlled
thermostat or you wish to connect your receiver manually as a result of
connection issues, proceed as follows...
… Press the ON / OFF button on the receiver and the LED lights up green
… The thermostat is in ON / OFF mode and the display lighting is on
(short press on any button).
… Press the “ - button” until “TEST” appears in the programme row of the
display. Press „Start“. The display now switches the ON / OFF display in
sync. Now press the ON / OFF button on the receiver for 3 seconds. The
LED display flashes quickly for a short time, then the display appears
in sync. The connection has now been established. Exit the connection
mode by pressing the “ON / OFF” button on your thermostat. Your
thermostat and receiver are now connected (paired).