LoRaWAN MC-LW-FCT-01 MClimate Fan Coil Thermostat User Manual
Introduction
Overview of the product
The MClimate Fan Coil Thermostat (FCT) also
supports the following additional inputs/outputs:
- Room occupancy/Key card input (opened/closed
circuit)
The Fan Coil Thermostat (FCT) is a LoRaWAN Thermostat for 2- and
4-pipe Fan Coil Units, accommodating 1-3 speed or ECM fans. Ideal
for building retrofitting, it enables room-by-room monitoring and
control, enhances energy efficiency and has great potential to
reduce heating/cooling expenses significantly. With its 4.2” e-ink
fast refresh display it allows the end-users to change the target
temperature and see current indoor conditions. Its fully open and
transparent communication protocol allows seamless integration
into different systems including MClimate Enterprise platform.
-
Auto-changeover external temperature sensor
(10k NTC, max 3m length)
- Dew point sensor (opened/closed circuit)
- Filter alarm (opened/closed circuit)
Functions
-
Maintenance of room temperature via built-in
temperature sensor or external room
temperature/return air temperature sensor
Automatic or manual changeover between
The MClimate FCT is
a
Class
C
LoRaWAN device, available for
EU868, US915, AS923 and AU915 regions. This means that there’s
real-time communication between the FCT and the LoRaWAN
network - commands can be sent to the FCT and it will respond as
soon as possible.
-
heating and cooling mode
- Selection of operating mode via the operating
mode button on the thermostat
MClimate’s ultimate aim is to help decarbonize buildings. The Fan
Coil Thermostat unlocks great retrofitting opportunities - one can
gain quick access to control and monitoring on a room-by-room
basis in the building.
- 1-speed, 3-speed or DC 0…10
(automatic or manual)
V
fan control
- Display of current room temperature or setpoint
in °C
- Minimum and maximum setpoint limitation
MClimate FCT can be integrated into existing BMS and BAS
- Buttons lock
systems. Please visit MClimate’s website to learn more about this.
- 1 digital input, freely selectable for:
- Occupancy mode contact (keycard)
- Automatic heating/cooling changeover 10k NTC
- Dew-point sensor
The MClimate Fan Coil Thermostat (FCT) can be used with the
following FCU configurations:
- Fault input
Advanced fan control function, e.g. fan kick,
selectable fan operation (enable, disable or
FCU
V
a
l
v
e
(
s
)
t
y
p
e
FAN type
Configuration
-
2-pipe
ON/OFF (220VAC)
1-3 speeds
00
depending on heating or cooling mode)
- Installer’s menu for setting the desired wiring
configuration and further settings.
2-pipe
4-pipe
4-pipe
2-pipe
2-pipe
3-wire ON/OFF (220VAC) 1-3 speeds
01
02
03
04
05
ON/OFF (220VAC)
ON/OFF (220VAC)
ON/OFF (220VAC)
1-3 speeds
ECM
ECM
3-wire ON/OFF (220VAC) ECM
Technical wiring diagrams for the different configurations are available further in the document.