hansgrohe 15384XXX RainSelect Thermostat Instruction Manual
English
Dimensions (see page 32)
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
inj uries.
The product may only be used for bathing, hygienic and body cleaning
purposes.
Children as well as adults with physical, mental and/ or sensoric impairments
must not use this product without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this product.
The hot and cold supplies must be of equal pressures.
�
Spare parts (see page 50)
�
�
�
XXX = Colors
000 = Chrome Plated
140 = Brushed Bronze
340 =Brushed Black Chrome
450 = White
610 = Black
670 = Matt Black
�
700 = Matt White
990 = Polished Gold-Optic
I nstallation I nstructions
•
•
•
Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
Cleaning (see page 49)
Operation (see page 48)
Test certificate (see page 52)
The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
The plumbing codes applicable in the respective countries must be observed.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
Test pressure:
0,1
-
0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60° C
Hot water temperature:
Connections G 1/ 2:
Thermal disinfection:
cold right - hot left
70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Safety Function (see page 42)
The desired maximum temperature for example max. 42º C can be pre-set thanks
to the safety function.
Adjustment (see page 42)
After the installation, the output temperature of the thermostat must be checked. A
correction is necessary if the temperature measured at the output differs from the
temperature set on the thermostat.
Maintenance (see page 44)
•
•
The check valves must be checked regularly according to EN 806-5 in
accordance with national or regional regulations (at least once a year).
To guarantee the smooth running of the thermostat, it is necessary from time to
time to turn the thermostat from total hot to total cold.
I nstallation example (see page 33)
i
Hot and cold supplies are reversed (see page 46)
Fault
Cause
Remedy
Insufficient water
- Supply pressure inadequate
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Regulator filter dirty
-
Clean filter in front of
mo cartridge
t
he mixer and on
t
he MTC-ther
-
- Shower filter seal dirty
- Clean filter seal between shower and hose
Crossflow, hot water being forced into cold water
pipe, or vice versa, when mixer is closed
Spout temperature does not correspond with
temperature set
- Backflow preventers dirty or leaking
- Clean backflow preventers, exchange if necessary
-
Thermostat has not been adj usted
- Hot water temperature too low
- thermo cartridge calcified
- Adj ust thermostat
- Increase hot water temperature to 42 ºC to 60 ºC
- Exchange thermo cartridge
Temperature regulation not possible
- Hot and cold supplies are reversed
- Spring defective
- (see page 46)
- Clean spring and/ or button, exchange if necessary
Safety stop button not operating
- Button calcified
Valve stiff
- Select stop valve DN9 damaged
- Select stop valve DN9 damaged
- Exchange Select stop valve DN9
- Exchange Select stop valve DN9
Shower drips continuously
Assembly (see page 37)
4
| General | Details |
|---|---|
| Name | hansgrohe 15384XXX RainSelect Thermostat Instruction Manual |
| Make | hansgrohe |
| Language | English |
| Filetype | PDF (Download) |
| File size | 10.29 MB |

hansgrohe Ecostat 1001 SL Shower Thermostat Instruction Manual

hansgrohe AXOR CARLTON Thermostat Mixer Instruction Manual

hansgrohe AXOR STARCK Concealed Thermostat with Shut Off Valve Instruction Manual

hansgrohe AXOR STARCK X Concealed Thermostat with Shut Off Valve Instruction Manual

hansgrohe AXOR URQUIOLA Concealed Thermostat with Shut Off Valve Instruction Manual

hansgrohe AXOR UNO2 Concealed Thermostat with Shut Off Valve Instruction Manual

Hansgrohe 13125000 Ecostat E Wall Mounted Shower Thermostat Instruction Manual

hansgrohe 24240XXX Shower Column Including Thermostat Instruction Manual

hansgrohe 15754000 Metris Classic Ecostat Classic High Flow Thermostat Instruction Manual