INSTALLATION INSTRUCTIONS
Diagram 2: 2-Way Communication Wiring (5 Pin / 5 Wire) - used
with AZ9V Models only. AZ9VH12DBMH1 & AZ9VH12EBMH1 will
require a software update.
To update, contact zoneline.requests@GEAppliances.com
Note: 2-way communication provides variable speed
models with temperature & humidity data to optimize
performance.
A link icon (see page 15) will be displayed on the
thermostat when a successful 2-way connection has
been made. Mode 6 on the VTAC will must be set to
“6u”.
For make up air models: To deliver make-up air only
when a room is occupied, be sure to enable mode “E”
in the auxiliary controls of the air conditioner.
Note: Colors Mentioned on Diagram Match Leads on
Zoneline 2-Way Connector below.
Red - R– 24V AC
Black - Common
Blue - Data A+
White/Blue - Data B-
Brown - RS485 GND