Bandary Smart thermostat FC610
Fan coil controller
Datasheet
Subject to technical alteration
Issue date: 28.08.2020
Application
The Dual-Right thermostat FC610, With Microcomputer control and WIFl communication technology to detect the difference
between room temperature and setting temperature,then through controlling the fan, ON/OFFvalve and modulating valve to keep
the room at comfortable and constant temperature This series product apply to control two pipe or four pipe fan coil ,two wire or
three wire motorized valve ,3-stage fan ,EC fan and an electrical heating water flow system . you can also control your thermostat
anyway where you are by APP in your cell phone ,with 1-way RS485 interface to BMS control system , can realize centralized
control and management.
| General | Details |
|---|---|
| Name | FC610 Bandary Smart Thermostat Owner’s Manual |
| Make | bandary |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.24 MB |

bandary FC660 Smart Thermostat User Guide

FC610 Bandary Smart Thermostat Owner’s Manual Overview
Summary of Contents
- Page 1: Bandary Smart thermostat FC610 Fan coil controller Application The Dual-Right thermostat FC610 features microcomputer control and WiFi communication technology to maintain a comfortable room temperature. It controls two pipe or four pipe fan coils, motorized valves, and various fan types. Users can control the thermostat remotely via an app on their cell phone. The device includes a 1-way RS485 interface for BMS control system integration. Centralized control and management are possible with this system. Subject to technical alteration. Issue date: 28.08.2020.
- Page 2: Security advice – caution The installation and assembly of electrical equipment should only be performed by authorized personnel. The product should only be used for the intended application. Unauthorized modifications are prohibited. The product must not be used in relation with any equipment that may threaten human health or life. Ensure all power is disconnected before installing. Do not connect to live/operating equipment. Risk of electric shock due to live components within the enclosure, especially devices with mains voltage supply. Please comply with local laws, health & safety regulations, technical standards and regulations. As a component of a large-scale fixed installation, Bandary products are intended to be used permanently. Most products may contain valuable materials that should be recycled and not disposed of as domestic waste. The room sensor should be mounted in a suitable location for measuring accurate room temperature. The accuracy of the temperature measurement depends on the temperature dynamics of the wall.
- Page 3: Technical data Controller cooling mode only, Comfort Mode Measuring values temperature Ventilating (PI loop controls fan stages only, valves closed) Output switch contact Fan Controller auto mode (heating & cooling), ECO Mode Input for external sensor NTC10K Network technology RS485 Modbus, RTU Power supply 24 DC/AC 50/60Hz Protection IP20 according to EN 60529
- Page 4: Mounting advices Dear customer, Thank you very much for choosing Bandary products. Ensure all power is disconnected before installing. Please install the product at normal temperature with good ventilation. This product should be installed on standard 86 *86 wall box and kept 60mm between two installation screws. Installation Description Step 1: Please follow the wiring diagram to connect the wires. Read-write system time—year Read-write setpoint temperature Read-write Controller Mode
- Page 5: Step 2: Fix the thermostat power box to the wall box through itself two installation screws with distance between axes of 60mm. Step 3: Fasten the power box and display unit. Don’t press the panel in order to protect LCD, and put the plastic cover on the panel to protect the panel. 7 day 4 periods programmable. 1 period: Start time hour 0-23h. 1 period: Start time minute 0-59m. 1 period: Start setpoint 0…500 -> 0…50,0°C. 2 period: Start time hour 0-23h. 2 period: Start time minute 0-59m. 2 period: Start setpoint 0…500 -> 0…50,0°C. 3 period: Start time hour 0-23h.
- Page 6: Dew Point Sensor (Open = Dewpoint crossed, disable cooling) Dew Point Sensor (Closed = Dewpoint crossed, disable cooling) Read-write configuration external input 2 Occupancy sensor (Open = Occupied) Window contact (Open = Window Open) Disable heating (Open = Heating disabled) Disable cooling (Open = Disable Cooling) Read-write configuration Sensor Input Energy Savings Input - ON delay Automatic Summer/winter time
- Page 7: Read-write electrical heater stage 3 threshold control variable. Valve type selection options include ON-OFF, PWM, OFF-ON, inverted PWM, and proportional. Modbus active indicates the device is connected to BMS via RS485 interface. Cooling mode activates when the set temperature is lower than room temperature. Ventilation mode operates the fan while keeping the water valve off. Heating mode activates when the set temperature is higher than room temperature. Auto mode allows the thermostat to switch between cooling and heating based on temperature differences. Temperature display shows room temperature or set temperature based on user adjustments. Function symbol indicates temperature setting, mode adjustment, or parameter setting status. Fault alarm displays an error symbol and code when an issue occurs.
- Page 8: Frost protection – In standby, the display is off, but the control loop actively monitors the temperature and will activate the heating output if the room temperature drops below the frost protection threshold. Scheduler – One day is divided into four periods. The user can set temperature for every period individually. ESI – Windows function detection. When the ESI symbol is lighted, it indicates the ESI function is active. Lock – The local thermostat will not be workable when this symbol is indicated unless it is released by the app on a smartphone, Modbus register, or the device power is off and restarted. ECO mode – ECO mode is active; the set temperature will be replaced by ECO. Fan stage symbol – Different fan speed display: low level, middle level, high level, and auto speed. Communication – The Bandary Thermostat FC610 supports Wi-Fi and Modbus dual communication. Change-over temperature threshold for heating – The range is from 0 to 500, corresponding to 0 to 50.0°C. Change-over temperature threshold for cooling – The range is from 0 to 500, corresponding to 0 to 50.0°C. Electrical heater stage threshold control variable – The range is from 0 to 100%.
- Page 9: Download the app for IOS devices by searching for Smart life in the Apple Store or scanning the QR code. For Android devices, search for Smart life in Google Play or scan the relevant QR code. Add the device in the app. Register an account in the app. In standby mode, long press the ON/OFF key for more than 3 seconds until the Wi-Fi symbol flashes. Click on the + symbol in Smart life, find the small home appliance menu, and click on the thermostat symbol. Input Wi-Fi account number and password in the app. Follow the guide to operate the next step; the app will automatically search for the device. In standby mode, press any point of the panel to switch on the panel. The thermostat will access screen saver mode after backlight delay time without any operation.
- Page 10: Indicator light settings include options for external inputs and temperature units. In normal mode, the indicator light and LCD display turn off after pressing the touch panel. The device allows for customer-set location identification and temperature unit selection. Temperature settings can be adjusted by rotating the first ring, with clockwise rotation increasing the temperature and anti-clockwise decreasing it. Fan speed can be adjusted using the second ring, with clockwise rotation increasing speed and anti-clockwise decreasing it. The internal and external sensor temperature offsets can be set within a range of -50 to 50 degrees Celsius. Screen saver mode can be configured to display temperature and humidity or temperature and clock. Individual password settings are available for mode selection, with a default password of 987. External temperature limiter sensor high and low limits can be set for temperature control. Power failure options determine the device's behavior after a power reset.
- Page 11: Ext. Temp sensor (NTC10K) Temperature Limiter Restore to factory default value: Input password “999” to restore to factory default value. Modbus communication Register: Input Register Wake up: In normal mode, the thermostat will access screen saver mode after the backlight delay time. Motion sensor: When the thermostat detects hand waving, it will wake up. Parameter Setting: Enter into Parameter Setting. Long press the touch panel for more than 6 seconds in Stand-By mode to enter the passwords. Read-only failure status: 0x00=no failure, 0x01=control loop temperature sensor alarm. If the password is correct, it will access the parameter setting interface.
- Page 12: Backlight intensity for screen saver Individual password Temperature format Communication ID Baud rate (bps) Parity Stop Bits Time setting Parameter table Frost protection
- Page 13: FCC warning This device complies with part 15 of the FCC Rules. Operation is subject to two conditions: it may not cause harmful interference and must accept any interference received. Any changes or modifications not expressly approved could void the user's authority to operate the equipment. Product name: Smart thermostat Model: FC610 This equipment has been tested and found to comply with the limits for a Class B digital device. If this equipment does cause harmful interference, the user is encouraged to try to correct the interference. To maintain compliance with FCC’s RF exposure guidelines, this equipment should be installed and operated with a minimum distance of 20 cm from the radiator. This device is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU.