Home > bandary > FC610 Bandary Smart Thermostat Owner’s Manual

FC610 Bandary Smart Thermostat Owner’s Manual

Stand:  
Seite 18 / 23  
90  
Stand:  
Seite 7 / 23  
303  
0x012F  
Read-write Electrical Heater Stage 3 Threshold control variable  
0..100%  
1.0  
%
Display panel  
304  
0x0130  
Read-write  
Valve type selection  
5DO:  
27.Fanstagesymbol  
0= ON-OFF (ON = Valve Open, OFF = Valve Closed)  
1=PWM (0%= 0%PWM .. 100% = 100% PWM)  
2= OFF-ON (OFF = Valve Open, ON = Valve Closed)  
3= inverted PWM (0%= 100%PWM .100% = 0% PWM)  
AO2DO3R, AO3DO2R:  
26.Thermostat address ID  
25.ECOmode  
24.Time delay  
1.Modbus active  
23.Wifisymbol  
2.Coolingmode  
22.Celsius  
3.Ventilation mode  
4.Heatingmode  
21.Electricheating  
4= proportional (0V = 0% ..10V = 100%)  
5=invers proportional (0V = 100% ..10V = 0%)  
6: proportional Belimo 6 way  
20.Fahrenheit  
19.Lock  
18.ESI  
5.Automode  
5DO:0  
6.Temperature display  
17.Scheduler  
AO2DO3R:4  
AO3DO2R:4  
7.Valve value  
16.Frost Protection  
15.Week  
7: proportional Sauter 6 way with Ø15mm  
8: proportional Sauter 6 way with Ø20mm  
9: proportional Belimo 6 way, counter direction  
10: proportional Sauter 6 way with Ø15mm,  
counter direction  
8.Function symbol  
9.Time setting  
14.Heatingvalve  
13.Coolingvalve  
12.Fault alarm  
11.Humidity  
10.TVOC  
1 Modbus active – When the device is connected to BMS via to RS485 interface ,the Modbus symbol will active.  
2 Cooling mode – when the set temperature is lower than room temperature ,the device will work in cooling mode.  
3 Ventilation mode - Fan is working, water valve keeps off.  
11: proportional Sauter 6 way with Ø20mm,  
counter direction  
4 Heating mode – when the set temperature is higher than room temperature ,the device will work in heating mode .  
DO5R,AO2DO3R, AO3DO2R:  
5 Auto mode –The thermostat switches automatically between cooling and heating according to the temperature difference between  
set temperature and room temperature. A time delay of approx..1min between cooling /heating mode changes is implemented to  
12: no valve  
ensure safe and eco-friendly operation .Auto mode will be active in below types:  
6 Temperature display – Normally ,the device displays room temperature .when the user change temperature ,it displays set  
305  
0x0131  
Read-write reserved  
0
temperature ,after 4 seconds ,display room temperature. (Factory default : display ),you can switch to Fahrenheit (°F) by APP or  
Modbus.  
Inputs  
7 Valve value – valve value%  
Address  
0x0150  
Access Description  
Resolution / Unit  
Default  
8 Function symbol – Temperature setting, Mode adjustment or Parameter setting status  
9 Time setting –Real time of Day  
336  
Read-write Configuration external input 1  
0 = No function  
10 TVOC – Room air quality  
1 = Occupancy sensor (Open = Occupied)  
2 = Occupancy sensor (Closed =Occupied)  
3 = Window contact (Open = Window Open)  
4 = Window contact (Closed = Window Open)  
5 = Disable heating (Open = Heating disabled)  
6 = Disable heating (Closed = Heating Disabled)  
7 = Disable cooling (Open = Disable Cooling)  
8 = Disable cooling (Closed = Disable Cooling)  
11 Humidity – Relative room humidity  
12 Fault alarm – ERROR alarm symbol and display ERROR code  
13 Cooling valve – Cooling mode is active .  
14 Heating valve – heating mode is active  
15 week-week display  
0
GeneralDetails
NameFC610 Bandary Smart Thermostat Owner’s Manual
Makebandary
LanguageEnglish
FiletypePDF (Download)
File size1.24 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
bandary FC660 Smart Thermostat User Guide
bandary FC660 Smart Thermostat User Guide

FC610 Bandary Smart Thermostat Owner’s Manual