Home > bandary > FC610 Bandary Smart Thermostat Owner’s Manual

FC610 Bandary Smart Thermostat Owner’s Manual

Stand:  
Seite 8 / 23  
Stand:  
Seite 17 / 23  
282  
283  
284  
285  
286  
287  
288  
289  
290  
291  
292  
293  
294  
295  
296  
297  
298  
299  
300  
0x011A  
0x011B  
0x011C  
0x011D  
0x011E  
0x011F  
0x0120  
0x0121  
0x0122  
0x0123  
0x0124  
0x0125  
0x0126  
0x0127  
0x0128  
0x0129  
0x012A  
0x012B  
0x012C  
Read-write PWM Cycle time  
DO5R: 0 = no PWM for valves but 2-point control  
16 Frost Protection – In Standby the display is off, but the control loop is actively monitoring the temperature and will activate the  
heating output if the room temperature drops below the frost protection threshold.  
17 Scheduler– one day is divided into 4 periods.The user can set temperature for every period individually. the user has set a set  
temperature during operation ,the current period runs with the last set temperature ,the next period will adopt the changed settings.  
18 ESI – Windows function detection, When ESI symbol is lighted indicates ESI function is active ( Optional )  
19 Lock – Local thermostat will not be workable when this symbol indicated unless it is released by APP on smart phone ,Modbus  
register or the device power off and restart .  
15  
10  
20  
30  
20  
30  
0
Read-write Deadband  
1...100 -> 0,1…10,0K  
0.1  
0.1  
1.0  
0.1  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
0.1  
0.1  
0.1  
K
°C  
min  
°C  
min  
%
Read-write Heating Proportional Band Xp_heat  
1...100 -> 0,1…10,0°C  
Read-write Heating Integration Time Tn_heat  
0...255 = 0…255 Minutes  
20 Fahrenheit (°F) – indicates Fahrenheit (°F) display  
Read-write Cooling Proportional Band Xp_cool  
21 Electric heating – indicates electric heating is active .The device has this function only in cooling only + Electric heater system  
22 Celsius(°C) – indicates Celsius(°C) display  
1…100 -> 0,1…10,0°C  
Read-write Cooling Integration Time Tn_cool  
23 Wifi symbol – 3- different status display:  
0…255 = 0…255 Minutes  
Blink in gap indicates the thermostat is offline  
Read-write Minimal limit of the control variable heat  
Rapid blink indicates the device is in pairing  
0..100  
Normal status indicates the thermostat connects to router or server successfully.  
24. Time delay symbol  
Read-write Maximal limit of the control variable heat  
%
100  
0
0..100  
25 ECO mode – ECO mode is active ,set temperature will be replaced by ECO .  
26 Thermostat address ID – Indicates the ID address on modbus .  
Read-write Minimal limit of the control variable cool  
%
0..100  
27 Fan stage symbol – Different fan speed display. Low level ( 3 pillars), Middle level ( 7 pillars), High level ( 10 pillars), Auto speed  
( “Auto” be shown) as below:  
Read-write Maximal limit of the control variable cool  
%
100  
5
0..100  
Read-write Fan stage 1 ON threshold control variable heat  
%
0..100  
Read-write Fan stage 2 ON threshold control variable heat  
%
35  
70  
5
0..100  
Read-write Fan stage 3 ON threshold control variable heat  
%
0..100  
Read-write Fan stage 1 ON threshold control variable cool  
%
Communication  
0..100  
Bandary Thermostat FC610 supports wifi and Modbus dual communication .  
Modbus communication :  
Read-write Fan stage 2 ON threshold control variable cool  
%
35  
70  
70  
0..100  
Read-write Fan stage 3 ON threshold control variable cool  
%
Communication-section  
Factory default:  
Address 0:  
1..247  
0..100  
1
Read-write Frost protection temperature threshold  
°C  
°C  
°C  
broadcast address  
50…150 -> 5,0…15,0°C  
Communication-Interface:  
Communication-Protocol:  
Baud Rate:  
RS485  
Read-write Change-Over Temperature Threshold for Heating  
300  
190  
Modbus-RTU  
0…500 -> 0…50,0°C  
4800 bps / 9600 bps / 19200 bps / 38400 bps (optional)  
Read-write Change-Over Temperature Threshold for Cooling  
0…500 -> 0…50,0°C  
Factory default:  
Parity:  
9600 bps  
In case temperature is in between both thresholds the  
last state will be maintained  
no parity / odd parity / straight parity (optional)  
Factory default:  
Data:  
no parity  
8 bit  
301  
302  
0x012D  
0x012E  
Read-write Electrical Heater Stage 1 Threshold control variable  
0..100%  
1.0  
1.0  
%
%
65  
80  
Stop:  
2 bit  
Read-write Electrical Heater Stage 2 Threshold control variable  
0..100%  
GeneralDetails
NameFC610 Bandary Smart Thermostat Owner’s Manual
Makebandary
LanguageEnglish
FiletypePDF (Download)
File size1.24 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
bandary FC660 Smart Thermostat User Guide
bandary FC660 Smart Thermostat User Guide

FC610 Bandary Smart Thermostat Owner’s Manual