Intellicomfort CH121E
1 - TECHNICAL FEATURES
Power supply
Battery duration
Contact range
2 AAA 1.5V batteries
approximately 1 year *
5(3)A 250V~
voltage-free switching
Maximum room temperature
Temperature adjustment scale
Measurement scale/room T display
Type of action
T45 °C
2 ÷ 40 °C, increase 0.1°C
-40 ÷ 50 °C
1B microdisconnection
Degree of protection
Pollution degree
IP20
2
Pulse voltage
4000V
Electric insulation
Double insulation
Class A
Software
Thermal gradient of reference
Assembly
4K/h
recessed in 3-module box type 503,
with 2 screws
Dimensions
68 x 52.2 x 58 mm
Compliant with standards
EN 60730-1 and second parts
ErP Class IV; 2% (Reg. EU 811/2013
- 813/2013)
ErP classification
Product not manufactured in Italy.
* N.B. the life of the batteries is greatly affected by the type of use and the
settings made by the user, especially the set back lighting switch-on time.
EN
- 4
CH121E istruzioni EN 5680075.indd
4
15/11/2024 12:09:29
| General | Details |
|---|---|
| Name | Fantini Cosmi CH121E Flush Mounting Thermostat User Manual |
| Make | Fantini Cosmi |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.42 MB |

Fantini Cosmi CH180-230V Touch Screen Programmable Thermostat Instructions

Fantini cosmi C820RQ Dual Power Room Thermostat Instruction Manual

Fantini Cosmi C800WIFI Programmable LED Thermostat Instruction Manual

Fantini Cosmi C820RQ LED Thermostat User Manual

Fantini Cosmi CH141E Battery Operated Weekly Programming Thermostat Owner’s Manual