6.4 Time
Cluster
(Chapter)
Attribute
Attribute Id Default Value
Data
type
Read/Write Manufactu- Reportable
(R/W)
rer Specific (Y/N)
(Y/N)
Time
No client attributes
N
N
6.5 Thermostat
Cluster
Attribute
Attribu- Default Value
te Id
Data
type
Read/Write Manu-
Repor-
(R/W)
facturer table
Specific (Y/N)
(Y/N)
Thermostat
Local Temperature
0x0000
0x29 (int16s)
0x20 (int8u)
R
N
N
Y
Pi Heating Demand
(valve position %)
0x0008
0x0010
0x00
R
N
Local Temperature
Calibration
0x00
0x28 (int8s)
0x29 (int16s)
RW
RW
N
N
N
N
Occupied Heating Set 0x0012
point
0x7D0 (20°C)
Unoccupied Heating
0x0014
0x0015
0x7D0 (20°C)
0x01F4 (5°C)
0x29 (int16s)
0x29 (int16s)
RW
R
N
N
N
N
Min Heat Setpoint
Limit
Max Heat Setpoint
Limit
0x0016
0x0BB8 (30°C)
0x29 (int16s)
R
N
N
Remote Sensing
0x001A 0x00
0x18 (8-bit bitmap)
RW
RW
N
N
N
N
Control Sequence of
Operation
0x001B 0x02 (Heating only) 0x30 (8-bit enum)
System Mode
TRV Mode
0x001C 0x04 (Heat)
0x30 (8-bit enum)
RW
RW
RW
R
N
Y
Y
Y
Y
N
N
N
Y
0x4000
0x4001
0x4002
0x4003
0x02 (MANU Mode) 0x30 (8-bit enum)
Set Valve Position
Errors
0x00
0x20 (int8u)
0x20 (int8u)
0x29 (int16s)
0x00
Current Temperature
Set point
0x7D0 (20°C)
RW
Y
Host Flags
0x4008
0x000000
0x24 (int24u)
RW
Y
N
– 15–
| General | Details |
|---|---|
| Name | EUROTRONIC SPIRIT ZigBee Energy Saving Thermostat User Guide |
| Make | EUROTRONIC |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.46 MB |

EUROTRONIC Sparmatic COMET Programmable Energy-Saving Radiator Thermostat User Manual

EUROTRONIC Programmable Energy-Saving Radiator Thermostat User Manual

eurotronic Comet Zigbee Energy Saving Radiator Thermostat Instruction Manual

EUROTRONIC COMET Programmable Energy Saving Radiator Thermostat User Manual

EUROTRONIC Spirit ZigBee Energy Saving Radiator Thermostat User Guide