5.4 Window open detection
Should the temperature fall suddenly, the window open detection mode is activated. The Spirit ZigBee
switches to the OFF mode for 15 minutes.
The window open mode is left automatically after 15 minutes and Spirit ZigBee restore its setpoint
temperature.
The sensitivity of the window open detection can be configured.
The window open detection can be terminated at a push of a button.
The window open detection is not executed in the actuator mode (Manufacturer-Specific Mode). The
window open detection can be activated/deactivated by an external window contact.
OFF
window open detection
enabled.
6 ZigBee Operation
Cluster
Endpoint
Cluster Id
0x0000
Server
Client
Basic
1
1
1
1
1
1
•
•
•
Power Configuration
Identify
0x0001
0x0003
0x000A
0x0201
0x0019
•
•
•
•
Time
Thermostat
OTA
•