Home > EPH CONTROLS > EPH CONTROLS CDC2 Cylinder Room Thermostat User Guide
EPH CONTROLS CDC2 Cylinder Room Thermostat User Guide
PO 1 Operating Mode (Normal
/ Delay Start / TPI)
Time Proportional Integral Mode (TPI)
When the thermostat is in TPI mode and the temperature is rising in the
zone and falls into the Proportional Bandwidth section, TPI will start to
affect the thermostats operation. The thermostat will turn on and off as
it gains heat so that it doesn’t overshoot the target by too much. It will
also turn on if the temperature is falling so it doesn’t undershoot the
target which will leave the user with a more comfortable level of heat.
There are 2 settings that will affect the thermostats operation
1. The number of heating cycles per hour
2. The Proportional Bandwidth
CyC – Number of Heating Cycles per hour
6 Cycles
This value will decide how often the thermostat will cycle the heating
on and off when trying to achieve the target temperature. You can
select 2/3/6 or 12.
Pb -Proportional Bandwidth
2°C
20
CDC2
| General | Details |
|---|---|
| Name | EPH CONTROLS CDC2 Cylinder Room Thermostat User Guide |
| Make | EPH CONTROLS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.66 MB |

EPH CONTROLS eTRV-HW Smart Cylinder Thermostat User Guide

EPH CONTROLS eTRV-HW Smart Hot Water Thermostat Instruction Manual

EPH CONTROLS eTRV Smart Radiator Thermostat Instruction Manual

EPH CONTROLS 20221026 RFRA – RF Room Thermostat Instruction Manual

EPH CONTROLS CDTP2 Hardwired Room Thermostat Instruction Manual

EPH Controls CDT2-24 24V Room Thermostat Installation Guide

EPH CONTROLS RFCA RF Cylinder Thermostat Instruction Manual

EPH CONTROLS PR092K7 RF Cylinder Thermostat Instruction Manual

EPH CONTROLS COMBIPACK2 Smart Thermostat with Automation and Optimum Start Instructions

EPH CONTROLS CRT2 Room Thermostat Instruction Manual