EMERSON 1F75C-11PR Programmable Thermostat Installation Guide
INSTALLER MENU (C0ntinued)
Installer’s Menu #
Description
Default Setting
Settings
(flashing icons)
(Hold Menu 8 Seconds)
Early Start (starts heating or
cooling early so your programmed
temperature is reached by the
programmed time)
On – start early
OFF – start at program
period time
OFF
76
°F – Fahrenheit
°C – Celsius
Fahrenheit or Celsius
°F
79
Temperature Display
Adjustment (adjust the displayed
“Room Temperature”)
0
-5 to +5
81
Continuous Display Light (keep
the backlight always on – “C” wire
required)
On – always on
OFF – momentarily
OFF
OFF
83
1 to 12 – reminder time
(months)
OFF – no filter reminder
Change Air Filter (set up a
monthly reminder)
86
TEST EQUIPMENT
Turn on power to the system.
Fan Operation
If your system does not have a G terminal connection, skip to Heating System.
1.) Move fan switch to On position. The blower should begin to operate.
2.) Move fan switch to Auto position. The blower should stop immediately.
Heating System
1.) Move System Switch to Heat position.
2.) Press to adjust thermostat setting to 1° above room temperature. The system should
begin to operate and the thermostat will indicate Heat On.
3.) Press to adjust thermostat setting 1° below room temperature. The heating system
should stop operating and the thermostat should indicate Heat.
Cooling System
1.) Move System Switch to Cool position.
2.) Press to adjust thermostat setting 1° below room temperature. The blower should
come on immediately on high speed, followed by cold air circulation. The thermostat will
indicate Cool On. There can be up to a 5 minute delay. (see INSTALLER MENU, item 50)
3.) Press to adjust thermostat setting to 1° above room temperature. The cooling system
should stop operating and the thermostat will indicate Cool.
Note: If Starting Soon is shown on the display, the compressor lockout feature is operating.
There will be up to a 5 minute delay before the compressor turns on.(see INSTALLER MENU,
item 50)
CAUTION
!
To prevent compressor and/or property damage, if the outdoor temperature is below 50°F,
DO NOT operate the cooling system.
Do not allow the compressor to run unless the compressor oil heaters have been operational
for 6 hours and the system has not been operational for at least 5 minutes.
4
| General | Details |
|---|---|
| Name | EMERSON 1F75C-11PR Programmable Thermostat Installation Guide |
| Make | Emerson |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.45 MB |

EMERSON ST75W Sensi Touch Wi-Fi Smart Thermostat Installation Guide

EMERSON Thermostat Common Wire Kit SA11 Instruction Manual

EMERSON 1F75H-21PR Programmable Heat Pump Thermostat Instruction Manual

EMERSON 1D56-310 White-Rodgers Low Voltage Horizontal Mounting Thermostat Instruction Manual

EMERSON Programmable Touchscreen Thermostat Setup in E2 and Site Supervisor User Guide

EMERSON 1F76U-22WFB Series Sensi Lite Smart Thermostat Installation Guide

EMERSON 1F87U-42WF Sensi Smart Thermostat User Guide

EMERSON 1F83C-11NP Single Stage Thermostat Owner’s Manual

EMERSON 1F75P-21PR Display Thermostat Instruction Manual

EMERSON 1F75H-21NP Non Programmable Heat Pump Thermostat Instruction Manual