Setting temperature calibration
After selecting the floor sensor type, you must set the calibration value (offset
value) of the sensor in order to minimize any variation in temperature
measurement.
To set temperature calibration:
1. Press + or – touch button on the device to set the calibration value between.
NOTE: The temperature calibration ranges from -9°C to +9°C and can be
adjusted in 0.5°C increments.
2. Set the calibration value, press the O touch button for > 1 s to confirm the
selection.
The thermostat dot-matrix display calibration value and
LED flashes purple.
Setting maximum guard temperature
After setting temperature calibration, you must set the maximum guard
temperature. It is upper limit of the floor sensor.
Minimum guard temperature can only be set through ELKO Smart app.
To set maximum guard temperature:
1. Press + or – touch button on the device to set the maximum limit.
NOTE: The temperature limit ranges from 11°C to 40°C.
2. Set the value, press the O touch button for > 1 s to confirm the selection.
The thermostat dot-matrix display calibration value and
LED flashes red.
IMPORTANT:
•
If you want to update the sensor settings manually after setting up the
device, Press O and + button simultaneously to enter preset selection and
press O to confirm preset and enter sensor setting.
•
•
You can also perform a factory reset to remove all settings and configure
It is possible to modify or update sensor settings without resetting the
thermostat with the ELKO Smart app. Refer app settings, page 19