ELKO EKO07258 16A Smart ZB Thermostat User Guide
Setting and operating the device manually
As a standalone thermostat, you can set the following settings and operating parameters.
Max
guard
temp.
setting
Floor
calibration
setting
Sensor
type
selection
Boost
mode
Standalone
schedule
Preset
x
x
x
x
x
x
P1
P2
P3
P4
P5
P6
P7
P8
P9
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
x
x
x
x
x
x
x
x
x
�
�
�
x
�
�
�
x
�
�
�
x
Device presetting
You can preset the thermostat on the first power-on or immediately after a factory
reset. The thermostat will require the selection of a preset to pre-configure settings
depending on what the thermostat is directly controlling, which allows the
thermostat to function correctly for the intended use case. Preset selection is a
manual process and all preset uses a PI control algorithm which provides highly
stable results.
You can choose one preset configuration:
Control type / Set
Configuration
Cycle time* (min)
Preset
point range
Heat Pump/Oil Boiler
Hydronic Radiator/Gas Boiler
Hydronic Underfloor
P1
P2
P3
P4
20
10
10
10
Room Control
4°C ~ 30°C
Electrical Radiator
Electrical Underfloor (Without
floor limits)
P5
P6
10
10
Electrical Underfloor (With floor
limits)
Hydronic Underfloor
Electrical Underfloor
P7
P8
10
10
Floor Control
10°C ~ 40°C
Regulator Mode (output
displayed is based on
percentage)
Floor Control
0 ~ 10 (0% ~ 100%)
P9
30
*Cycle time: This setting determines the length of each on/off cycle of the output
relay. The percentage of time within that cycle time that the relay is on is varied
based on demand. A longer cycle time may be more appropriate for slow heating
DUG_ZB Thermostat 16 A_ELKO-00
7