Technical Data  
Nominal voltage:  
AC 230 V ~, 50 Hz  
Maximum current rating  
Resistive load:  
Inductive load:  
max. 16 A, 3520 W  
max. 4 A  
Standby:  
max 0.5 W  
Connecting terminals:  
Neutral conductor:  
Ambient temperature:  
Relative humidity:  
Temperature accuracy:  
Screw terminals for max. 2.5 mm², 0.5 Nm  
Required  
0 to 40 °C  
max. 90% non-condensing  
max. ±0.5 °C (accross the range of 4 to 30 °C)  
max. 0.1 °C  
Temperature measurement resolution:  
Display:  
7x5 dot matrix, 3 additional LEDs  
2.401 GHz to 2.483 GHz  
< 10 mW  
Operating frequency:  
Max. radio-frequency power transmitted:  
Communication protocol:  
Floor sensor types:  
Zigbee 3.0 certified  
10, 12, 15, 33, 47 (Thermistor resistance values in kOhm. Nominal value  
at 25 °C)  
Protection Class:  
Working voltage:  
II  
230 V  
Over-voltage category:  
Rated impulse voltage:  
Pollution degree:  
III  
4 kV  
2
CTI rating of insulation components:  
Material group:  
175 V  
IIIa (based on CTI value)  
1.B  
Disconnection type:  
44  
DUG_ZB Thermostat 16 A_ELKO-00  
 
GeneralDetails
NameELKO EKO07258 16A Smart ZB Thermostat User Guide
MakeELKO
LanguageEnglish
FiletypePDF (Download)
File size1.63 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
elko One Matter Thermostat Owner’s Manual
elko One Matter Thermostat Owner’s Manual
ELKO EKO50107, EKO50108 Matter Thermostat Installation Guide
ELKO EKO50107, EKO50108 Matter Thermostat Installation Guide

ELKO EKO07258 16A Smart ZB Thermostat User Guide