For heat pump systems, its also crucial to understand what the minimum outdoor temperature that the heat pump  
can run with - otherwise the thermostat will lock out the heat pump and change over to aux heat as the weather  
outside will be too cold to run the heat pump unit that is sitting outside.  
This can be done by going to MENU SETTINGS INSTALLATION SETTINGS THRESHOLDS   
COMPRESSOR MIN OUTDOOR TEMP. This is set at a default 35F (1.7C), so the heat pump will not be used when  
the weather outside is below 35 degrees Fahrenheit and only aux heat will be used in this case.  
To also avoid short cycling and increase equipment efficiency, you can go to MENU SETTINGS   
INSTALLATION SETTINGS THRESHOLDS HEAT DIFFERENTIAL TEMP and change this to a higher value  
so that the system turns on for a larger temperature drop and reduces short cycling.  