Setting up an ecobee for ventilator control:  
The ventilator control capabilities depend on the type of ventilator installed which can be either a HRV, ERV or  
standard Ventilator.  
There minimum runtime setting when the home is occupied and when unoccupied. The ventilator will also run for  
60 minutes prior to occupancy, this is called pre-purge and is not user adjustable but can be enabled or disabled.  
Regardless of the type of ventilator the minimum runtime settings are used to force the ventilator to run a specific  
number of minutes per hour. This runtime is broken into 15-minute blocks to evenly spread out the runtime  
throughout the hour, but at a minimum 5 minutes of runtime is required. So, if the runtime was set to 10 minutes,  
the time is broken into two 5-minute blocks.  
Ventilator Minimum On  
Time While Away: The  
number of minutes per hour  
the fan is required to run  
when the house is  
Ventilator Minimum On  
Time While Home: The  
number of minutes per  
hour the fan is required to  
run when the house is  
considered occupied  
considered unoccupied  