Compressor Stage 2 Temperature Delta: The minimum number of degrees from the desired temperature (set  
point) before engaging the second stage of the compressor. This is set to auto by default.  
You will only see this option if you have a two-stage compressor (wires in both Y1 and Y2)  
Compressor Reverse Staging: With this setting enabled, you will also need to enable the Compressor Stage 2  
Temperature Delta threshold setting listed above and set a temperature value. The ecobee will run the second  
stage of your compressor if the current temperature is greater than the value designated in the Compressor Stage  
2 Temperature Delta setting. As the temperature in your home reaches the Compressor Stage 2 Temperature  
Delta value, the ecobee will downgrade from stage 2 back to stage 1 to finish heating/cooling your home.  
You will only see this option if you have a two-stage compressor (wires in both Y1 and Y2)  
If enabled, this setting will cancel out Compressor Stage 1 Max Runtime  
Compressor Stage 1 Max Runtime: The maximum number of minutes running stage 1 before engaging the  
second stage of the compressor.  
You will only see this option if you have a two-stage compressor (wires in both Y1 and Y2)  
Two Stage Furnace Settings:  
Heat Stage 2 Temperature Delta: The minimum number of degrees from the desired temperature (set point) before  
engaging the second stage of furnace heat. This is set to auto by default.  
You will only see this option if you have a two-stage furnace (wires in both W1 and W2)  
Heat Stage 1 Max Runtime: The maximum number of minutes running stage 1 before engaging the second stage  
of the furnace.  
You will only see this option if you have a two-stage furnace (wires in both W1 and W2)  
Aux Heat Settings (Heat Pumps with Aux Heat):  
Aux Heat Max Outdoor Temperature: The auxiliary heat will not run when the outdoor temperature is above this  
point. If you are receiving many “Aux heat running alerts,” you may want to lower this setting—this will maximize  
the use of your heat pump while limiting the use your aux heat.  
Aux Heat Minimum On Time: The minimum amount of time your auxiliary heat will stay on during a call for aux heat.  
This is set to 300 seconds (5 minutes) by default. If your aux heat is engaged and then the call for heat is  
immediately cancelled, the aux heat will continue running for this set value (5 minutes) before turning off. This  
setting prevents your aux heat from short cycling, so we recommend leaving this at 300 seconds to prevent any  
potential damage to your equipment.  
25 Dockside Drive, Suite 700  
Toronto, ON M5A 0B5  
ecobee.com  
GeneralDetails
Nameecobee M5A Smart Wi-Fi Thermostat User Guide
MakeEcobee
LanguageEnglish
FiletypePDF (Download)
File size2.48 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

ecobee M5A Smart Wi-Fi Thermostat User Guide