OPERATINGYOUR THERMOSTAT  
CAUTION  
Check Thermostat Operation  
!
NOTE  
To prevent compressor and/or property damage, if the  
outdoor temperature is below 50°F, DO NOT operate  
the cooling system.  
To prevent static discharge problems, touch side of  
thermostat to release static build-up before touching  
any keys.  
Cooling  
If at any time during testing your system does not operate  
properly, contact a qualified service person.  
1. Press SYSTEM to select "Cool".  
2. Press  
to adjust the thermostat setting below room  
temperature. The blower should come on immediately on  
high speed, followed by cold air circulation. The display  
should show "System On". If the setpoint temperature  
display is flashing, the compressor lockout feature is  
operating (see Configuration menu, item 11).  
Fan Operation  
If your system does not have a G terminal connection, skip to  
Heating System.  
1. Turn on power to system.  
3. Adjust temperature setting to 3° below room temperature.  
The second stage cooling should begin to operate and the  
display should show "System On +2".  
2. Press FAN key to ON position. The blower should begin  
to operate.  
3. Press FAN key to AUTO position. The blower should  
stop immediately.  
4. Press  
to adjust the temperature setting above room  
temperature. The cooling system should stop operating.  
CAUTION  
Donotallowthecompressortorununlessthecompressor  
oil heaters have been operational for 6 hours and the  
system has not been operational for at least 5 minutes.  
!
Choose the Fan Setting (Auto or On or Prog)  
There are two fan features  
1. Fan Auto/On - Traditional Fan Settings  
Press Fan to select Auto or On. The most commonly  
used setting is Auto. Fan Auto runs the fan only when the  
heating or cooling system is operating. Selecting Fan On  
runs the fan continuously for increased air circulation or to  
allow additional air cleaning if the system is equipped with  
an Electronic Air Cleaner.  
Heating  
1. Press SYSTEM key to select HEAT. If the auxiliary heating  
system has a standing pilot, be sure to light it.  
2. Press  
to adjust thermostat setting to 1° above the  
room temperature. The heat pump system should begin  
to operate. The display should show "System On".  
However, if the system configuration is set to HP1 or  
HP2 and setpoint temperature display is flashing, the  
5 minute compressor lockout feature is operating (see  
Configuration menu, item 11).  
2. FAN Prog - Comfort Circulating fan Feature  
Pressing Fan until FAN Prog appears activates the  
Comfort Circulating Fan Option. This causes the  
thermostats to cycle the fan on for 10 minutes and off for  
20 minutes if the thermostat has not called for heat or  
cool during the past 60 minutes. This assures moderate  
air circulation even when the heating and cooling  
equipment is not cycling.  
3. Adjust temperature setting to 3° above room temperature.  
If your system configuration is set at MS2, HP1 or HP2,  
the auxiliary heat system should begin to operate and the  
display will show "System On +2".  
Choose the System Setting  
(Cool, Off, Heat, Em, Auto)  
4. Press  
to adjust the thermostat below room  
temperature. The heating system should stop operating.  
Press the SYSTEM key to select:  
Cool: Thermostat controls only the cooling system.  
Emergency Mode  
Applies only to Heat Pump Systems  
Off: Heating and Cooling systems are off.  
Heat: Thermostat controls only the heating system.  
Emergency Heat (System EM Position) bypasses the Heat  
Pump to use the heat source wired to terminal W/E, W2  
on the thermostat. EM is typically used when compressor  
operation is not desired, or you prefer back-up heat only.  
Em: Setting is available only when the thermostat is  
configured in HP1 or HP2 mode.  
Auto: Auto Changeover is used in areas where both heating  
and cooling may be required on the same day. AUTO allows  
the thermostat to automatically select heating or cooling  
depending on the indoor temperature and the selected heat  
and cool temperatures. When using AUTO, be sure to set the  
Cooling temperatures more than 1° Fahrenheit higher than  
the heating temperature.  
1. Press SYSTEM key to select EM. “EM Heat Mode” will  
flash on the display.  
2. Press  
to adjust thermostat setting above room  
temperature. The Emergency heating system will begin to  
operate. The display will show “System On” flashing “EM  
Heat Mode” and “Heat” to indicate that the Emergency  
system is operating.  
Manual Operation for  
Non-Programmable Mode  
3. Adjust temperature setting to 3° above room temperature.  
Any additional stages of auxiliary heat should begin to  
operate and the display will show "System On +2".  
Press the SYSTEM key to select "Heat" or "Cool" and use  
the keys to adjust the temperature to your desired setting.  
After selecting your desired settings you can also press  
the SYSTEM key to select AUTO to allow the thermostat to  
4. Press to adjust the thermostat below room  
temperature. The heating system should stop operating.  
automatically change between "Heat" and "Cool".  
9
GeneralDetails
NameBlue Universal OH-1202 Touchscreen Thermostat Instruction Manual
MakeBlue Universal
LanguageEnglish
FiletypePDF (Download)
File size0.4 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

Blue Universal OH-1202 Touchscreen Thermostat Instruction Manual