Connecting the floor temperature sensor / remote control system  
Insert the floor sensor wires through one of the two  
openings on the wallplate and connect them to  
terminals 1 and 2 (no polarity).  
TE  
ST  
The sensor wires must not come in contact with the  
electrical wires and must be routed outside the  
electrical box and follow the wall down to the floor.  
Position the sensor cable such that it does not  
come in contact with the floor heating wires. The  
sensor must be centered between two floor heating  
wires for best temperature control.  
Do NOT staple the sensor head (the plastic end) to  
the floor. Doing so might damage the sensor. Any  
damage might not be noticeable during testing but  
can become apparent several days later.  
Floor  
temperature  
sensor  
If you wish to connect a remote control device (see  
page 11), insert the wires (use 18- to 22-gauge flexible  
wires) through one of the two openings on the wallplate  
and connect them to terminals 2 and 3 (no polarity).  
M39037  
Remote control device  
8
GeneralDetails
Nameaube TH114-AF-GA Non-Programmable Thermostat Owner’s Manual
Makeaube
LanguageEnglish
FiletypePDF (Download)
File size0.69 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
aube Electronic Thermostat TH131 Owner’s Manual
aube Electronic Thermostat TH131 Owner’s Manual
aube TH146-P-2H1C Programmable Thermostat Installation Guide
aube TH146-P-2H1C Programmable Thermostat Installation Guide

aube TH114-AF-GA Non-Programmable Thermostat Owner’s Manual