Floor temperature limits (AF mode only)  
The minimum and maximum floor temperature limits are available only if the temperature control mode is AF (see page 9).  
If the floor temperature drops below the minimum limit or rises above the maximum limit, the thermostat will turn heating On  
or Off respectively, regardless of the ambient temperature, to maintain the floor temperature within the set limits.  
NOTE: The desired ambient temperature might not be attainable if the maximum floor temperature is set too low.  
The minimum and maximum floor temperature limits are factory-set at 10 °C (50 °F) and 28 °C (82 °F) respectively. To  
modify the limits, proceed as follows:  
WARNING: To avoid damaging your floor, follow your floor supplier’s recommendations regarding floor temperature limits.  
Switch the thermostat to Off.  
While pressing either  
perature limit settings.  
button, switch the thermostat back to On to access the floor tem-  
Press the Backlight button briefly to switch between minimum and maximum floor temperature  
settings.  
M39019  
Press the  
buttons to set the desired limit.  
Press the Backlight button for 3 seconds to save your modifications. After the data are saved,  
the thermostat displays the current temperature or “– –”.  
M39020  
NOTE: Your modifications are automatically saved if no button is pressed for 60 seconds.  
10  
GeneralDetails
Nameaube TH114-AF-GA Non-Programmable Thermostat Owner’s Manual
Makeaube
LanguageEnglish
FiletypePDF (Download)
File size0.69 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
aube Electronic Thermostat TH131 Owner’s Manual
aube Electronic Thermostat TH131 Owner’s Manual
aube TH146-P-2H1C Programmable Thermostat Installation Guide
aube TH146-P-2H1C Programmable Thermostat Installation Guide

aube TH114-AF-GA Non-Programmable Thermostat Owner’s Manual