Home > Aprilaire > Aprilaire 8570 Premium Programmable Thermostat Instruction Manual

Aprilaire 8570 Premium Programmable Thermostat Instruction Manual

3. OFFSET  
4. DEADBAND  
5. PROGRESSIVE RECOVERY  
To turn Progressive Recovery on or off:  
All thermostats are factory calibrated to be accurate to within  
1° of true temperature. An offset is available to allow for  
agreement with field temperature measuring instruments. The  
value set will be added to the temperature sensed by the  
thermostat. The result will be displayed on the thermostat and  
will be used as the control value.  
This is the number of degrees (in either °F or °C) that the heat  
setting must be lower than the cool setting. The thermostat will  
automatically adjust the temperature setting not being changed  
to maintain this difference.  
Progressive Recovery causes the thermostat to bring on the  
heating/cooling equipment before the programmed event start  
time, in order for the temperature to be at the programmed  
value by the programmed time. The feature can be turned on  
or off. When turned off, the heating/cooling equipment will  
not begin bringing the space temperature to the programmed  
value until the start of the event.  
1. Make sure the thermostat is in the OFF mode.  
2. Press and hold both the ▲ and ▼ buttons for 3 seconds.  
– The display will show the ADV. SETTINGS MENU.  
3. Use the ▲ or ▼ button to highlight “PROGRESSIVE  
1. Make sure the thermostat is in the OFF mode.  
RECOVERY” and press the SELECT button.  
2. Press and hold both the ▲ and ▼ button for 3 seconds.  
– The display will show the ADV. SETTINGS MENU.  
3. Scroll down through the menu items and select SETTINGS.  
4. To cancel, press the BACK button  
To change the offset:  
5. To change whether Progressive Recovery is on or off,  
press the ▲ or ▼ button to highlight either ON or OFF.  
1. Make sure the thermostat is in the OFF mode.  
2. Press and hold both the ▲ and ▼ buttons for 3 seconds.  
– The display will show the ADV. SETTINGS MENU.  
4. Use the ▲ or ▼ button to highlight “DEADBAND” and press  
6. To finish and return to the ADV. SETTINGS MENU, press  
the SELECT button.  
the SELECT button.  
3. Use the ▲ or ▼ button to highlight “SET OFFSET” and  
5. To cancel, press the BACK button. This will return you to the  
SETTINGS MENU.  
press the SELECT button.  
4. To cancel, press the BACK button.  
6. To change, use the ▲ or ▼ button to scroll to either 2°  
or 5°.  
5. To change the offset value, press the ▲ or ▼ button to  
raise or lower the setting between –4° and +4° (°F or °C).  
7. To finish and return to the ADV. SETTINGS MENU, press the  
SELECT button.  
6. To finish and return to the ADV. SETTINGS MENU, press  
the SELECT button.  
- 38 -  
- 39 -  
GeneralDetails
NameAprilaire 8570 Premium Programmable Thermostat Instruction Manual
MakeAprilaire
LanguageEnglish
FiletypePDF (Download)
File size0.57 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Aprilaire 8538 Digital Heat Cool Thermostat Owner’s Manual
Aprilaire 8538 Digital Heat Cool Thermostat Owner’s Manual
AprilAire S86W MUPR WiFi Thermostat User Guide
AprilAire S86W MUPR WiFi Thermostat User Guide
Aprilaire S86N MU Multi Stage Universal Thermostat Instruction Manual
Aprilaire S86N MU Multi Stage Universal Thermostat Instruction Manual
Aprilaire S86WMUPR Programmable Wi-Fi Multi Stage Universal Thermostat Installation Guide
Aprilaire S86WMUPR Programmable Wi-Fi Multi Stage Universal Thermostat Installation Guide
Aprilaire S86N MUPR Multi Stage Universal Thermostat Owner’s Manual
Aprilaire S86N MUPR Multi Stage Universal Thermostat Owner’s Manual
Aprilaire S84N 1H1C Programmable Single Stage Universal Thermostat Owner’s Manual
Aprilaire S84N 1H1C Programmable Single Stage Universal Thermostat Owner’s Manual

Aprilaire 8570 Premium Programmable Thermostat Instruction Manual