Home > Amana > Amana DS01G Digi Smart Thermostat Instruction Manual

Amana DS01G Digi Smart Thermostat Instruction Manual

6B. Drill a 7/32” holes and tap plastic anchors into wall.  
Screw mounting base plate to wall. DO NOT SNAP  
THERMOSTAT INTO PLACE UNTIL AFTER BINDING  
PROCESS. See Binding Instructions on page 10. Proceed  
to Step 7.  
Thermostat Installation for DS01G Kit  
NOTE: A DT01* must be installed on the digital PTAC unit  
for the DS01* to be operable.  
Skip these steps if not installing.  
4C. If mounting thermostat to one or two gang  
electrical box, discard flush-mount base extension.  
Screw mounting base plate to electrical box.  
Screws not included. DO NOT SNAP  
THERMOSTATINTO PLACE UNTILAFTER  
BINDING PROCESS. See Binding Instructions on  
page 10.  
1. Select thermostat mounting location about five feet  
above the floor, on an inside wall, out of direct sunlight,  
away from sources of radiant heat (lamps, fireplaces,  
heating and air conditioning equipment, etc.), away  
from windows or door to the outside, and avoid areas  
with poor air circulation. If the PIR in the thermostat is  
to be used with a DD01* device as a 2nd motion sensor,  
point the thermostat towards the area where you are  
requiring additional motion sensing.  
7. Install two (2) AA batteries (included) into the back of  
the thermostat. Terminals are marked “+” and “-” for  
polarity.  
Ensure location is out of the path of foot traffic where  
a person might accidentally bump into the thermostats  
and damage the device.  
NOTE: Do not install thermostat on wall plate until all  
configuration settings and binding processes have been  
completed.  
2. Set flush-mount base extension aside from mounting  
base plate.  
WIREDPOWEROPTION  
3. Remove thermostat from mounting base plate by gently  
pulling apart at the bottom of the thermostat about 1”,  
and slide thermostat up to release from the top of the  
mounting base plate. If mounting thermostat flush to  
wall proceed to step 4A. If mounting thermostat with  
battery compartment recessed into drywall proceed to  
step 4B, or if mounting thermostat to an electrical box  
proceed to step 4C.  
1. If the option for wired power is used, the two thermostat  
wires (20 gauge minimum field supplied) can be  
connected to the thermostat.  
2. Route wires through the rectangular opening on the flush  
mount base plate base extension if used, and through  
the label in the area marked by a circle on the mounting  
base plate.  
4A. Place flush-mount base extension against the wall  
at desired location and mark placement of the right  
mounting hole and top mounting holes. Make sure  
rectanglular opening is on the left side so that when  
mated with the mounting base plate the UP arrow is  
pointing up on the mounting base plate.  
3. Loosen set screws on wired terminals labeled 24VAC and  
insert wires into the opening. Tighten set screws. (See  
following figure for powered connection with 2 jumpers).  
Move jumper from the two pins furthest from the battery  
block to the two pins nearest the battery block.  
5A. If mounting in drywall, drill 7/32” holes, tap plastic  
anchors into wall. For other surfaces, drill hole as  
required.  
4. Connect wires at PTAC unit to terminal pins C and R.  
The wire harness kit PWHK01C is required for this  
connection.  
6A. Screw mounting base plate and flush-mount base  
extension assembly to the wall. DO NOT SNAP  
THERMOSTAT INTO PLACE UNTIL AFTER BINDING  
PROCESS. See Binding Instructions on page 10.  
Proceed to step 7.  
WIRED DOOR SWITCH OPTION  
NOTE: Thermostat has motion sensing capability for  
energy management operation, and thermostat may be  
connected to a wired door switch or may work in  
conjunction with a wireless door switch or wired door  
switch connected to the PTAC.  
4B. If mounting thermostat with battery compartment  
recessed into drywall, cut drywall opening 2” wide  
by 2&7/8” tall in desired location. The flush-mount  
base extension may be used as a template. Due  
care should be taken if wiring, plumbing or other  
contents behind the wall are unknown.  
1. If connecting a wired door switch to this thermostat (20  
gauge minimum field supplied) can be connected to  
the thermostat.  
5B. Discard flush-mount base extension. Place the  
mounting base plate against the wall in the desired  
location and mark placement of right mounting hole  
and top mounting hole. Make sure the UP arrow is  
pointing up on the mounting base plate.  
2. Route wires through the rectangular opening on the  
flush mount base plate base extension if used, and  
through the label in the area marked by a circle on  
the mounting base plate.  
3
GeneralDetails
NameAmana DS01G Digi Smart Thermostat Instruction Manual
MakeAmana
LanguageEnglish
FiletypePDF (Download)
File size0.66 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Amana MMW-2 Horizontal Digital Wireless non EMS Wall Thermostat Instruction Manual
Amana MMW-2 Horizontal Digital Wireless non EMS Wall Thermostat Instruction Manual
Amana ATST-CWE-BL-A Smart Thermostat Owner’s Manual
Amana ATST-CWE-BL-A Smart Thermostat Owner’s Manual
Amana DS01 PTAC Wireless Thermostat User Manual
Amana DS01 PTAC Wireless Thermostat User Manual

Amana DS01G Digi Smart Thermostat Instruction Manual