Vaillant VRT15 Room Thermostat User Guide
myVAILLANT connect internet gateway
with heat pumps
Vaillant heat pumps can be installed with a myVAILLANT connect internet gateway to enable use with the myVAILLANT app. Not only
can the app provide homeowners with the energy consumption, energy yields and efficiencies of their heating system, but it can
also enable you to see how your customers heat pump is performing with myVAILLANT Pro Service.
Monitor your customers systems with myVAILLANT Pro. myVAILLANT Pro Service will show you the energy efficiency of your
customers heat pump, the energy consumption, heat generated and more. This will enable you to advise your customers on the best
way they can use their Vaillant heat pump.
Depending on the heat pump system installed, the VRA 42 or AC adapter three pin plug should be used to power the myVAILLANT
connect. the VRA 42 can be purchased from your local merchants with a gateway or separately.
Depending on the heat pump system, either the VRA 42 or AC adapter three pin plug should be used:
⬤
aroTHERM plus
⬤ with a VWZ MEH 97/6 hydraulic module can use the VRA 42
⬤ with a VIH QW 190/6 uniTOWER can use the VRA 42
⬤ with a VWZ AI VWL x/6 MB2 should use the three-pin plug solution
⬤
⬤
aroTHERM split with either the VWL 57/5 IS, VWL 77/5 IS or VWL
125/5 IS hydraulic modules can use the VRA 42
aroTHERM 2/3 with VWZ AI VWL x/2 A should always use the three-pin
plug solution
⬤
⬤
geoTHERM mini can use the VRA 42
flexoTHERM should use the three-pin plug solution
Visit our YouTube channel for a range of ‘how to’ videos to support your customers.
Please note: both AC adapter and the VRA 42 are included in the pack (0010038367).
25
Boiler Plus
All of Vaillant’s current range of controls or combination of controls exceed the requirements of the Boiler Plus legislation
introduced in 2018. We have always been proud to provide our customers with the most efficient controls on the market.
Sustainability and efficiency are at the heart of everything we do.
What is Boiler Plus?
Boiler Plus is government legislation that aims to regulate and improve the way homes use energy by increasing the efficiency
of their heating systems. If you’re looking to update your customers heating system, or simply want to ensure your customer is
receiving the best efficiency possible, we’ll help you understand the steps necessary to comply with the government regulation, as
well as answer a number of questions frequently asked on the topic.
There are a number of ways you can comply with the Boiler Plus regulations. We have outlined the absolute requirements below:
Your heating system must meet or exceed an Energy Related Products (ErP) efficiency of 92% during operation.
All installations must have time and temperature controls fitted, if they aren’t already present and working correctly.
How to comply?
In addition, combination boilers, which make up a significant proportion of the market will require one of four additional
requirements to be fitted. It will mean each installation will include a consultancy aspect needed for each boiler swap. The measures
available are:
Load compensation - the ability to modulate the flow temperature from the boiler based on the actual room temperature, this
requires the control and boiler to ‘speak’ the same language.
Weather compensation - the ability to modulate the flow temperature from the boiler based on the outdoor temperature.
Smart control - a control that provides automation and optimisation.
Passive Flue Gas Heat Recovery - a method of preheating a hot water demand by utilising any excess heat in the flue.
What’s new?
As of late 2022, Boiler Plus standards have been introduced in Scotland and Wales with some slight differences to those set in
England.
Boiler Plus in Wales
Boiler Plus policy in Wales introduces the requirement for the smart thermostat to also feature remote access.
For a complete solution that meets the four additional measures of Boiler Plus in Wales, we would recommend pairing an ecoTEC
exclusive with a sensoHOME or sensoCOMFORT with an internet gateway.
Boiler Plus in Scotland
Boiler Plus policy in Scotland meanwhile has been expanded to apply to all gas boiler replacements (so includes system and open
vent boilers as well as combination).
Control requirements remain the same as England.
26
Tested. Secure. Peace of mind.
Vaillant works with VDE to ensure data is secure
The VDE institute is an independent and neutral European technical-scientific association that tests and certifies electrotechnical
devices, components and systems. They test products for their safety, electromagnetic compatibility and other product
characteristics.
Products carrying the VDE mark have been independently assessed against international standards and legal protection
requirements.
One of the areas the VDE works in is the assessment of products and services for smart home security.
All of Vaillant’s products have been rigorously tested and have met VDE’s strict testing criteria for approval by the Institute. You can
therefore rest assured that Vaillant products are secured and protected to the highest level.
27
| General | Details |
|---|---|
| Name | Vaillant VRT15 Room Thermostat User Guide |
| Make | Vaillant |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.5 MB |

Vaillant VRC 700 Weather Compensating Thermostat Instruction Manual

Vaillant VRC 700 Programmable Weather Compensating Thermostat Owner’s Manual

vaillant VR 92f/3 Wireless Additional Room Thermostat Instructions

Vaillant VRT 51f sensoROOM Wireless Room Thermostat Instruction Manual

Vaillant senso Comfort Thermostat Instructions