Home > Thermogroup > Thermogroup Thermotouch 4.3dC Dual Control Thermostat Installation Guide
Thermogroup Thermotouch 4.3dC Dual Control Thermostat Installation Guide
Installing Thermotouch
4. Wiring diagram
Connect Thermotouch to the Underfloor Heating (UFH) cold tail,
Heated Towel Rail (or another additional appliance), power supply
and floor temperature sensor.
The floor temperature sensor is not polarity sensitive. If using a DC transformer when
installing a low voltage appliance to the 5A relay an inrush limiting device must be installed
9
8
7
6
5
4
3
2
1
UFH Live (16A)
UFH Neutral (16A)
Heated Towel Rail Neutral (5A)
230V AC Supply Neutral
230V AC Supply Live
Heated Towel Rail Live (5A)
Common Earth (Ground)
Sensor connections
|
1300 368 631