Home > Thermogroup > Thermogroup Thermotouch 4.3dC Dual Control Thermostat Installation Guide
Thermogroup Thermotouch 4.3dC Dual Control Thermostat Installation Guide
Advanced Settings
To access the settings press Menu, then the green Settings icon.
In this menu you can set up and control all of the more advanced
settings for your Thermotouch Thermostat.
Description
Range
Default
27°C
5°C
High Temp. Protection
Low Temp. Protection
Max. Set Temp.
Floor Temp. Calibration
Ambient Temp. Calibration
Sensor Calibration
Rail Control
20°C - 40°C
5°C - 15°C
5°C - 40°C
-10°C - 10°C
-10°C - 10°C
See page 3
ON, OFF
30°C
0°C
0°C
Ther
ON
UFH Control
ON, OFF
ON
Language
English, French, German English (En)
Restore
NO, YES
NO
Adaptive Start
Window Detect
Detect Time
ON, OFF
OFF
ON, OFF
OFF
2 - 30 minutes
2, 3, 4°C
15 mins
2°C
Drop Temp.
Delay Time
10 - 60 minutes
30 mins
|
1300 368 631