Before you start
Thermotouch 4.3dC should be:
• Installed at least 1.2m from the floor
• On an interior wall
• In an area outside any wet zones (IP30)
• Installed on a RCD protected circuit
• Away from drafts or heat influences
• Installed so that the floor sensor probe can be laid in a clear,
temperature representative area of the floor
• Set to floor sensing mode wherever possible
• In an open area of the room
• Installed by a qualified electrician in accordance with local
electrical regulations
• Installed with an inrush limiting device when using a DC
transformer on the 5Amp relay
|