VI. Operation Instruction
BOT series boiler thermostats are with LCD digital display big screen,
and it is developed according to market’s requirements. Thermostats can
be installed on the wall, or directly put on the table. This series thermostats
are easy to operate, and with complete functions. It can be used to
control boilers, motorized ball valves, motorized valves, electric valves,
solenoid valves, etc.
Time Setting
Press
or
, the time area will display Minute, Hour and Week, then press
to modify time.
Programmable Period Temperature Setting
II. Technical Parameter:
Set, or modify parameter
Working Voltage
USB type C (5V)
A Week Loop Control
3. Press one time, time twinkles,
you can set the time during this period.
time during this period.
Current Load
3A
6 periods every day
in a week
1. After Power is on, long press 5 seconds
to enter period program. Loops means a
Week loop.
2. Press again, room temperature display
and twinkle, you can set the temperature
during this period.
±1ºC (0.5-4.5℃ adjustable)
Temperature Control Accuracy
Setting Temperature Range
5+2 Controls 1 2 3 4 5
6+1 Controls 1 2 3 4 5 6
7+0 Controls 1 2 3 4 5 6 7
5-35℃
4. Press again, to set the next period
temperature and time with the same method.
Limiting Temperature Range
Consumption
5-35ºC
First step, long press
, screen display LooP(Cycling Control), screen
<0.3W
displays 12345 (From Monday to Friday); Press
123456(From Monday to Saturday); Press
1234567(From Monday to Sunday);
one time, it displays
two times, it displays
Temperature Sensor
NTC
III. Main Button Instruction
: ON/OFF Switch;
Second step, time and temperature setting in every period. When screen
display 12345 or 123456 or 1234567, press to enter temperature setting.
Press
Att: When auto-control
to enter time setting. To modify and save through
or
,if user needs to reset the temperature, it can
.
:Mode Button. Switch between Manual Mode,
Control Mode, Temporary Manual Mode. Long press to enter
period setting.
Auto Period
be changed to temporary manual control. Temporary manual control means
when thermostat is in auto-control mode(program mode), user press
:Time Set. Hour, minute and week setting;
or
to modify temperature setting, thermostat now is in temporary manul
:Up Button. To increase temperature. When press it with
it can set programmable function;
and
and
control state. When next periods comes, thermostat will automatically
return to acquiescent period program control mode.
:Down Button. To reduce temperature. When press it with
it can set programmable function;
Programmable Period Time Setting
: Key Lock. Long press
:
IV. User Interface Explanation
5 seconds to lock or unlock;
First press
time in the period.
, then press
to change to time options, user can modify
Default Program Data
Default Temperature
Period
Icon Default Time
1
2
3
4
5
06:00
08:00
11:30
20℃
15℃
15℃
15℃
22℃
Workday
12:30
17:30
22:00
08:00
6
15℃
22℃
1
2
Weekends
23:00
15℃
Att:
1.The default temperature values of 3 and 4 period
in workday is same with 2 period. If user need,
please change this default temperature.
2. Setting temperature is 00, it means this period
is power off.
:Manual Control.
:Heating.
:Temporary Manual Control. :Auto Control.
:First Period. Wake up in the morning.
VII. Advanced Setting
:Second Period. Out of home in the morning.
:Third Period. Go home in the afternoon.
:Forth Period. Out of home in the afternoon.
:Fifth Period. Go home in the evenning.
:Sixth Period. Sleep in the evening.
: Anti-frozed function open.
Firstly, press time button
Then, press power button
Open/Close State Power
Power Indicator Light
State Indicator Light
Switch Indicator Light
After entering advanced setting, press to
choose next parameter changing.
In the state of power-off, long press and hold
setting mode. Then press to set relative item.
then press into advanced
| General | Details |
|---|---|
| Name | BEOK CONTROLS BOT306RF WIFI Boiler Thermostat Instruction Manual |
| Make | BEOK CONTROLS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.31 MB |

BEOK CONTROLS TDR83 WiFi Heating Thermostat User Guide

BEOK CONTROLS TCR7 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual

BEOK CONTROLS TDR89 Thermostat User Guide

BEOK CONTROLS BOT-R7X Wireless Gas Boiler Heating Thermostat Instructions

BEOK CONTROLS TCR8 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual

BEOK CONTROLS TGW60 Touch Screen Boiler Thermostat User Guide

BEOK CONTROLS TGR86 WiFi Thermostat User Guide

BEOK CONTROLS BOT-323W Series Boiler Thermostat Instruction Manual

BEOK CONTROLS TDS72 Digital Screen Thermostat Instruction Manual

BEOK CONTROLS BOT-R6W Gas Boiler Thermostat Instruction Manual

BEOK CONTROLS BOT306RF WIFI Boiler Thermostat Instruction Manual Overview
Summary of Contents
- Page 1: BOT series boiler thermostats are developed according to market requirements. Thermostats can be installed on the wall or placed on a table. This series is easy to operate and has complete functions. It can control various types of valves and electric devices. Time setting allows modification of minute, hour, and week. Programmable period temperature setting includes multiple control options. Temperature control accuracy is ±1ºC with a range of 5-35ºC. The user interface includes buttons for mode switching and temperature adjustments. Default program data includes specific time and temperature settings for weekdays and weekends. Advanced settings allow for additional configuration and control options.
- Page 2: For Android system, download the Beok RFBoiler app from Google Play. Thermostat settings include limit temperature return difference and upper/lower limits. Press the UP button for 10 seconds to measure temperature. The anti-frozen function can be opened or closed. To connect the thermostat with your phone, press the thermostat button for 10 seconds in the turn-off state. Enter your Wi-Fi name and password to configure the connection. The wiring diagram includes normally closed and normally open interfaces. Installation wires should be 1.5-2.5mm² hard line, and connections must follow the diagram. The thermostat features a children lock and an anti-freezing function. Temperature setting can be adjusted by dragging the pointer or pressing buttons.
- Page 3: Advanced setting: Long press senior to switch manual mode. Switch of manual mode and auto mode: Press to toggle between modes. Power off: Press to turn on or off the thermostat. CHK (Check) code: Ensure all SN are correct and consistent with the barcode. Installation instruction: Follow steps to set sequence number correctly. In the box you will find: Thermostat, user manual, screws, receiver, USB cable, support bracket. Warranty: 24 months from the sales day for quality issues. Sequence number: Each thermostat has a matched receiver with a unique sequence number. In advance setting, SNP needs to be set to 01 before setting SN. Boiler thermostat BOT306 series: Follow specific steps to enter parameter setting and modify numbers.