Home > Hycontrol > Hycontrol HY08AC Central Air Conditioning Thermostat Instruction Manual

Hycontrol HY08AC Central Air Conditioning Thermostat Instruction Manual

Operation  
Fan Speed  
Description  
WIFI fan coil unit thermostat manual  
Power on state ,press to choose fan speedhigh  
mid  
low  
)、  
Search for "Smart RM" or Smart Life”  
Turn on the thermostat, press and hold  
Download the Wifi App from Google Play or  
APP Store  
the key combination “  
and “  
Auto  
animation)  
Activate WIFI distribution network icon  
Power on state, press“ ”3-5s chose  
Minutemmflashingpressorto adjustpressto next setting.as  
same method to set hour and week.finally press or wait 5S to exit  
then press“ ” to set time:  
Setting time  
Timer  
Technical data  
After connected wifi ,click cloudon the right corner of APP to set  
Voltage: AC90~240V,  
OutputOn/off type  
Power on state,long press“ ”3-5S, short press  
to choose ,next press  
Current: 3A  
Display temperature range0~70°C  
Work environment:-10~60°C  
Size86 * 86mm  
to choose mode:  
Accuracy: ±0.5ºC  
Setting range: 5ºC - 35ºC  
Sensor:NTC(10k)1%  
Button  
Working mode  
Control valve  
is mean cooling mode,“ ”is mean heating mode,“  
is mean  
ventilation modeis mean auto mode  
When cooling mode(heating mode),indoor temperature morelower) 1than  
setting temperature, open valve; after equal, closed valve,fan is still running.  
Ventilation modefan is not control by temperature as default)  
Icon  
Description  
Increase key: short press to adjust data,long press to check external senor temperature  
(When the sensor type is N3 in the advanced option)  
If fan be controlled by temperature,then valve and fan will be closed.  
Locked  
function  
Alarm  
Mode switching key: short press to switch between manual mode and program mode,  
long press to set special function parameters  
long press  
to lock/unlock keys  
E1 inner sensor alarm  
Decrease keyshort press to adjust data, long press to lock/unlock keys  
Fan speed selection key: short press to set fan speed (confirm key when setting  
parameters), long press to enter sleep function setting  
E2 external sensor alarm  
Sleep mode  
Power on state, long press  
,
is flashing, short press  
to run itshort  
Power key  
press  
to cancel  
Press them together to enter matching wifi mode  
RemarkSleep mode is not available when run ventilate mode or auto mode  
Manual/  
Power on state, short press“ ” to switch manual mode/program mode  
WIFI connection, flashing as EZ wifi pair mode  
program mode  
Wifi status: Disconnection  
Child lock  
Program mode setting  
cloud icon ,if flashing ,then enter AP wifi pair mode  
Program mode;run preset program  
Temporary manual mode  
Thermostat support set different time and different temperatureCompatible with 5+2,6+1,7days  
Manual mode  
Program mode type  
Clock  
Holiday mode, Holiday days and temperature can be set to run in countdown mode  
Long press  
3-5Snext short press  
to choose  
then short press  
to program mode  
Operation  
settinguse  
and to adjust value . After short press  
to set next time section setting  
GeneralDetails
NameHycontrol HY08AC Central Air Conditioning Thermostat Instruction Manual
MakeHycontrol
LanguageEnglish
FiletypePDF (Download)
File size0.23 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

Hycontrol HY08AC Central Air Conditioning Thermostat Instruction Manual
Get the free PDF manual for the Hycontrol HY08AC Central Air Conditioning Thermostat Instruction Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Hycontrol HY08AC Central Air Conditioning Thermostat Instruction Manual Overview

Summary of Contents

  • Page 1: Operation Fan speed selection allows users to choose between high, mid, and low settings. To activate the WiFi distribution network, press and hold the designated key combination. Download the WiFi app from Google Play or the App Store for setup. Setting the time involves pressing specific keys to adjust minutes and hours. Technical data includes voltage specifications and operational parameters. The thermostat supports various working modes, including cooling, heating, ventilation, and auto mode. Alarm indicators such as E1 and E2 signal inner and external sensor issues. The device features a sleep mode that is not available in ventilation or auto modes. Program mode allows for setting different temperatures for different days. Child lock function is available to prevent unauthorized changes.
  • Page 2: Time section includes settings for Monday to Sunday with default times and temperatures. The default temperature is set to 20°C, with options to adjust for external sensors between 20-60°C. Advanced options include standby brightness settings and temperature calibration ranging from -9 to +9°C. Children lock settings allow for half lock (adjustable temperature) or full lock (no adjustments). Cautions on installation emphasize avoiding high fluctuation displays and proper mounting height at 1.5m. Thermostat installation should avoid corners, door/window sides, and unheated areas. Ensure power supply cables are well insulated and do not open the internal circuit board. The thermostat is designed for a standard 75x75x35mm wall mount box. Before installation, ensure the system is disconnected and meets voltage requirements (Max. AC Voltage: 250V). Sensor options include inner, external, and double sensors, with specific conditions for valve and fan operation.
  • Page 3: Page 3