Operation
Fan Speed
Description
WIFI fan coil unit thermostat manual
Power on state ,pres“s ”to choose fan speed(high
)、(mid
)、(low
)、
Search for "Smart RM" or “Smart Life”
Turn on the thermostat, press and hold
Download the Wifi App from Google Play or
APP Store
the key combination “
” and “
”
(Auto
animation)
Activate WIFI distribution network icon
Power on state, press“ ”3-5s ,chose
Minute“mm”flashing,press“ ”or“ ”to adjust,press“ ”to next setting.as
same method to set hour and week.finally press or wait 5S to exit
,then press“ ” to set time:
Setting time
Timer
Technical data
After connected wifi ,click “cloud” on the right corner of APP to set
Voltage: AC90~240V,
Output:On/off type
Power on state,long press“ ”3-5S, short press
to choose ,next press
Current: 3A
Display temperature range:0~70°C
Work environment::-10~60°C
Size:86 * 86mm
to choose mode:
Accuracy: ±0.5ºC
Setting range: 5ºC - 35ºC
Sensor:: NTC(10k)1%
Button
Working mode
Control valve
“
” is mean cooling mode,“ ”is mean heating mode,“
”is mean
ventilation mode; is mean auto mode
When cooling mode(heating mode),indoor temperature more(lower) 1℃ than
setting temperature, open valve; after equal, closed valve,fan is still running.
Ventilation mode(fan is not control by temperature as default)
Icon
Description
Increase key: short press to adjust data,long press to check external senor temperature
(When the sensor type is N3 in the advanced option)
If fan be controlled by temperature,then valve and fan will be closed.
Locked
function
Alarm
Mode switching key: short press to switch between manual mode and program mode,
long press to set special function parameters
long press
to lock/unlock keys
E1 :inner sensor alarm
Decrease key:short press to adjust data, long press to lock/unlock keys
Fan speed selection key: short press to set fan speed (confirm key when setting
parameters), long press to enter sleep function setting
E2 :external sensor alarm
Sleep mode
Power on state, long press
,
is flashing, short press
to run it,short
Power key
press
to cancel
Press them together to enter matching wifi mode
Remark:Sleep mode is not available when run ventilate mode or auto mode
Manual/
Power on state, short press“ ” to switch manual mode/program mode
WIFI connection, flashing as EZ wifi pair mode
program mode
Wifi status: Disconnection
Child lock
Program mode setting
cloud icon ,if flashing ,then enter AP wifi pair mode
Program mode;run preset program
Temporary manual mode
Thermostat support set different time and different temperature;Compatible with 5+2,6+1,7days
Manual mode
Program mode type
Clock
Holiday mode, Holiday days and temperature can be set to run in countdown mode
Long press
3-5S,next short press
to choose
,then short press
to program mode
Operation
setting,use
and to adjust value . After short press
to set next time section setting
| General | Details |
|---|---|
| Name | Hycontrol HY08AC Central Air Conditioning Thermostat Instruction Manual |
| Make | Hycontrol |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.23 MB |

Hycontrol HY08AC Central Air Conditioning Thermostat Instruction Manual Overview
Summary of Contents
- Page 1: Operation Fan speed selection allows users to choose between high, mid, and low settings. To activate the WiFi distribution network, press and hold the designated key combination. Download the WiFi app from Google Play or the App Store for setup. Setting the time involves pressing specific keys to adjust minutes and hours. Technical data includes voltage specifications and operational parameters. The thermostat supports various working modes, including cooling, heating, ventilation, and auto mode. Alarm indicators such as E1 and E2 signal inner and external sensor issues. The device features a sleep mode that is not available in ventilation or auto modes. Program mode allows for setting different temperatures for different days. Child lock function is available to prevent unauthorized changes.
- Page 2: Time section includes settings for Monday to Sunday with default times and temperatures. The default temperature is set to 20°C, with options to adjust for external sensors between 20-60°C. Advanced options include standby brightness settings and temperature calibration ranging from -9 to +9°C. Children lock settings allow for half lock (adjustable temperature) or full lock (no adjustments). Cautions on installation emphasize avoiding high fluctuation displays and proper mounting height at 1.5m. Thermostat installation should avoid corners, door/window sides, and unheated areas. Ensure power supply cables are well insulated and do not open the internal circuit board. The thermostat is designed for a standard 75x75x35mm wall mount box. Before installation, ensure the system is disconnected and meets voltage requirements (Max. AC Voltage: 250V). Sensor options include inner, external, and double sensors, with specific conditions for valve and fan operation.
- Page 3: Page 3