Table 1. FUNCTION MENU
Menu section
CONTROL FROM THE BUTTONS
Screen
Notes
Press
button «≡»
After switching on the thermostat will start to display the
sensor temperature. If it is below the current set
temperature, voltage is applied to the load. The indicator
starts to glow red.
Hand mode. Adjustable via the app or controller
buttons. It allows you to maintain one pre-set
temperature.
Robot mode
(factory setting «hnd»
— Hand mode).
1 time
Use «+» or «–» to change the heating temperature. The
screen will first display the operating mode, then the set
temperature of this mode.
The controller has
Schedule mode. Adjustable via the app. If the
Preheat feature is enabled on the app, the screen
will display «Prh».
4 operating modes.
One of two modes
can be set from the
thermostat buttons only:
«hnd» — Hand mode
or «Sch» — Schedule mode.
For viewing of necessary section of the menu press
certain number of times button «≡». For the selection
and change use buttons «+» and «–». 5 seconds after
the last push of the buttons, there is a return to the
temperature display.
Temporary mode. If to change the temperature of
the setting in the mode Schedule to the timetable,
the thermostat will support it until the end of the
current period. The outcome from the temporary
mode under: the return of the setting back, the
shutdown of the supply, turning on of the period of
the leaving.
Away mode. Is tuned only by means of the app. For
the cancellation of the mode Away withhold middle
button during 4 seconds to the apparition of «oFF»
in the indicator. After release of the button the
thermostat will return in the acting mode before
beginning of the period of the Away.
Button blocking (child and public
protection)
In order to enable (disable) button blocking
press the «+» and «–» buttons at the same
time for 6 sec till up to appearance in
indicator «Loc» or running line («unLoc»).
Installed load
capacity
(factory setting 2.0,
a range of change 0,01...25,0 кW,
the step length depends
on power capacities)
2 times
Adjustable via the app or controller buttons. For
proper operation of energy consumption statistics, it
is required to insert installed load capacity.
Reduce to factory reset
For reset of all settings to factory (besides
Wi-Fi settings) press button «–» during
30 second. before emergence on the screen
of the inscription «dEF». After release of the
button thermostat will reload.
Floor
3 times
4 times
Adjustable via the app or controller buttons. If
necessary, it is possible to make correction to the
floor temperature at Indicator of the thermostat.
temperature correction
(factory setting 0,
a range of change ±9,9 °С,
step 0,1 °С)
Viewing of firmware version (current
firmware version F2.4)
The brightness
in the mode of waiting
(factory setting 6,
With 0 in the screen only points will be displayed:
left — indicator of the presence of the tension of the
power supply; middle — is reflected state of loading;
right — is reflected state of Wi-Fi net.
Holding button «–» during 12 seconds will
display on the screen the version of insertion.
After release of button, thermostat will return
to the normal mode.
a range of change 0...9)
PIN-code or local IP
(the section is available
when connected thermostat
to a Wi-Fi network)
when
When Wi-Fi is turned off, the item is unavailable.
When connected to the cloud, it outputs a PIN-code
for registration. When you connect to Wi-Fi, but the
lack of communication with the cloud will output
your local IP address.
If the firmware version of thermostat does not meet the
version mentioned in the manual, download from
website Operation Manual for the required version. The
website address can be found in the instructions in the
Contacts section.
connection
to a Wi-Fi
network
5 times
Operating mode Wi-Fi
(factory setting «Cli»
— Client mode)
when
Access point mode.
Client mode.
connection
to a Wi-Fi
network 6 times
otherwise
5 times
Our company reserves the right to make changes to its
firmware, cloud interface and applications for iOS and
Android for improving the energy efficiency of the device
and for optimizing its operation.
Wi-Fi is turned off.
Enabling sleep mode
Remote management
blocking by
thermostat
(factory setting
«LАn» — blocking of changes
through local area network)
when
Switched of.
Hold the «≡» button for 4 seconds (3 dashes
will appear on the display one by one) before
appearing on the display «oFF». For a
complete shutdown, the circuit breaker should
be turned off.
connection
to a Wi-Fi
network 7 times
otherwise
6 times
Switched on blocking of changes from «cloud».
Switched on blocking of changes through local area
network.
To disable sleep mode, also hold down the
middle button for 4 seconds until «on» pops
up on the screen.
Total blocking of management from the cloud. It is
possible to change parameters only using buttons of
the thermostat.
9
10
11
12
| General | Details |
|---|---|
| Name | terneo rzx Smart Thermostat User Manual |
| Make | terneo |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.25 MB |

terneo v3G33 Simple Heat Control Thermostat Instruction Manual

terneo BeeRT Digital Thermostat Instruction Manual

terneo bx Smart Thermostat Instruction Manual