CONNECT THE AUXILIARY OUTPUT  
CONNECT YOUR THERMOSTAT TO YOUR APPLICATION  
CONNECT AN EXPANSION UNIT (TR1310)  
1
If you do not have an account yet,  
It is possible to connect up to 10 expansion units to the  
same device. (EXP function)  
Second heating stage (15 sec / 15 min functions)  
download the Neviweb app for iOS or  
Android to open an account and add  
your device.  
TH1310WF  
TR1310  
TR1310  
Transformer  
24 VCA  
Tap the  
then select "Add Device"  
2
To others  
TR1310  
Baseboard  
Convector  
Follow the steps of the Installation Wizard  
3
DISCONNECT YOUR THERMOSTAT FROM THE  
WI-FI ROUTER OR THE NEVIWEB APP  
GROUND FAULT PROTECTION  
To disconnect your thermostat from the Wi-Fi router press the  
The thermostat is equipped with a ground fault protection that can  
detect a current leakage of 5 mA. When a current leakage is detected,  
the ground fault protection is triggered and quickly interrupts the power  
supply to prevent any serious injuries.  
and  
buttons simultaneously for 10 seconds. The  
symbol  
will disappear from the display.  
TROUBLESHOOTING GUIDE  
What should I do if the E1F code appears on  
my thermostat display?  
Resetting the ground fault protection  
The RESET button warning light turns ON (red) when the ground  
fault protection is triggered. If the RESET button warning light turns  
ON during normal operation of the thermostat, simply press the  
RESET button to reset the ground fault protection. The light will turn  
OFF. If for any reason this situation occurs again, cut the power to  
the heating system from the main electrical panel and ask a  
qualified electrician to verify the installation.  
The E1F code means that the thermostat is in  
“Floor” mode and there is no connected  
sensor. If your thermostat is not intended to  
control an heated floor, change the  
thermostat’s control mode for the “A mode”.  
Testing the ground fault protection  
This thermostat has an Auto Test which periodically verifies the  
correct operation of the protection circuit. You can also do this  
manually:  
1) Press the TEST button. If the RESET button's, red warning light does  
not turn ON, the test has failed. Cut the power to the heating system  
from the main electrical panel and ask a qualified electrician to verify  
the installation.  
10 sec.  
2) Press the RESET button to restart the thermostat's base.  
To remove your thermostat from Neviweb, press Delete in  
the thermostat settings.  
TECHNICAL SPECIFICATIONS  
Operating voltage: 120/208/240 Vac, 50/60 Hz  
Maximum load:  
1800 W @ 120 V / 15 A  
3120 W @ 208 V / 15 A  
3600 W@ 240 V/ 15 A  
Trasmitter module IC: 21098-ESPWROOM32 / FCC ID: 2AC7Z-ESPWROOM32  
This device complies with Industry Canada license exempt RSS standard(s). Operation is subject to the  
following two conditions:  
(1) this device does not cause interference, and (2) this device must accept any interference, including  
interference that may cause undesired operation of the device.  
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant  
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful  
interference in a residential installation. This equipment generates, uses and can radiate radio frequency  
energy, and if not installed and used in accordance with the instructions, may cause harmful interference  
to radio communications. However, there is no guarantee that interference will not occur in a particular  
installation. If this equipment does cause harmful interference to radio or television reception, which can  
be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the  
interference by one or more of the following measures:  
Setpoint range: 5 °C to 36 °C (41 °F to 96 °F)  
Display range: 0 °C to 50 °C (32 °F to 99 °F)  
Resolution: 0.5 °C ( 1 °F)  
Storage: -20 °C to 50 °C (-4 °F to 122 °F)  
Auxiliary output: 24 Vac/Vdc / 0.1 A  
GFCI protection: Class A (5mA)  
Protocole : Wi-Fi  
Standard: IEEE 802.11 b/g/n  
Frequency: 2.4 GHz  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
Consult the dealer or an experienced radio/TV technician for help.  
Controlling this HomeKit-enabled accessory automatically and  
away from home requires a HomePod, Apple TV, or iPad set  
up as a home hub. It is recommended that you update to the  
latest software and operating system.  
3-year limited warranty  
SINOPE TECHNOLOGIE INC. warrants the components of their products against  
defects in material and workmanship for a 3-year period from the date of purchase,  
under normal use and service, when proof of purchase of such is provided to the  
manufacturer. This warranty does not cover any transportation costs that may be  
incurred by the consumer. Nor does it cover a product subjected to misuse or  
accidental damage. The obligation of SINOPÉ TECHNOLOGIE INC., under the terms  
of this warranty, will be to supply a new unit and this releases the manufacturer from  
paying the installation costs or other secondary charges linked to replacing the unit  
or the components.  
Use of the Works with Apple badge means that an accessory has been designed to work  
specifically with the technology identified in the badge and has been certified by the  
developer to meet Apple performance standards. Apple is not responsible for the operation  
of this device or its compliance with safety and regulatory standards.  
HomeKit is a trademark of Apple Inc.  
Neviweb® is a registered trademark of Sinopé Technologies Inc. in Canada and the United  
States.  
Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other  
countries.  
App Store is a service mark of Apple Inc., registered in the U.S. and other countries. Google  
Play and the Google Play logo are trademarks of Google Inc.  
The Wi-Fi CERTIFIED™ Logo is a certification mark of Wi-Fi Alliance®  
For more information, visit our Website:  
660-0735-0024-B  
GeneralDetails
Namesinope Smart Floor Heating Thermostat TH1310WF Installation Guide
Makesinope
LanguageEnglish
FiletypePDF (Download)
File size1.11 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
sinope TH1134ZB-HC Smart Line Voltage Thermostat Owner’s Manual
sinope TH1134ZB-HC Smart Line Voltage Thermostat Owner’s Manual
sinope Smart Low Voltage Thermostat TH1400WF Installation Guide
sinope Smart Low Voltage Thermostat TH1400WF Installation Guide
sinope TH1124NP Non Programmable Thermostat for Electric Heating Owner’s Manual
sinope TH1124NP Non Programmable Thermostat for Electric Heating Owner’s Manual
sinope TH1300ZB-C4 3600W Smart Floor Heating Thermostat Installation Guide
sinope TH1300ZB-C4 3600W Smart Floor Heating Thermostat Installation Guide
sinope TH1400NP Non Programmable Low Voltage Thermostat Installation Guide
sinope TH1400NP Non Programmable Low Voltage Thermostat Installation Guide
sinope TH1134ZB Smart Line Voltage Thermostat Installation Guide
sinope TH1134ZB Smart Line Voltage Thermostat Installation Guide
sinope TH1500ZB Smart Double Pole Thermostat Installation Guide
sinope TH1500ZB Smart Double Pole Thermostat Installation Guide
sinope TH1500WF Smart Double Pole Thermostat Installation Guide
sinope TH1500WF Smart Double Pole Thermostat Installation Guide

sinope Smart Floor Heating Thermostat TH1310WF Installation Guide