Home > Schneider > Schneider Drayton Digistat 3rd Generation Wireless Programmable Room Thermostat User Guide

Schneider Drayton Digistat 3rd Generation Wireless Programmable Room Thermostat User Guide

1b.Installation of the wallplate  
Fixing(minimum wallplate clearances shown below)  
Digistat  
3rd Generation  
i. Loosen the securing screws, remove the wallplate, and if  
surface wiring is to be used, snap out the cable entry strip  
on the bottom edge of the wallplate with a pair of pliers.  
ii. Fix the wallplate, terminals at the top, either direct onto the  
Wireless Programmable  
Room Thermostat  
Model: RF901  
N
L
1
2
3
4
Consists of Thermostat RF90T and ReceiverRF90S  
Technical Helpline Tel: 0333 6000 622  
Website:  
100 mm  
E
m
a
i
l
:
c
u
s
t
o
m
e
r
.
c
a
r
e
@
d
r
a
y
t
o
n
c
o
n
t
r
o
l
s
.
c
o
.
u
k
User and Installation Guide 06490310001 Iss C  
Installation Guide  
Before Installation  
(Fig 2)  
If you do not have the knowledge to install the thermostat safely  
then you must arrange for a competent electrician to install it for  
you. Wiring must conform to the current IEE regulations.  
2. Wiring  
This product is double insulated and does not require an earth  
connection. The receiver should be wired to the combi boiler or  
Prior to commencing the installation you must ensure the  
mains supply is switched off.  
The receiver should be wired in to replace hard-wired room  
or programmable thermostats shown on the system or boiler  
wiring diagrams. Always check other manufacturers’ instructions  
for compatibility.  
1. Installing the Digistat Receiver  
1a. Location of the receiver  
Location  
The Digistat Receiver should be mounted in a convenient  
position, close to the boiler or central heating system wiring  
centre. (Care should be taken not to mount the receiver in  
a position where it is surrounded by metal objects or mains  
voltage cable, as this may interfere with the radio signal). For  
the best performance install in an open space, at least 30cm  
distance from any metal objects including wall boxes and  
boiler housing.  
Relay Output  
Opentherm Output  
It is recommended that the receiver is mounted on the wall  
Digistat Thermostat room  
thermostat and not less than 30cm from the boiler side panel.  
Warning: Installing the receiver too close to the metal side  
panel or mains cables may interfere with the radio signal.  
30cm Min  
(Fig 3)  
BOILER  
REC  
Radio Signal Range:  
30m Typically  
The range may be affected by  
composition/density and number of  
walls between the Digistat thermostat  
and receiver  
Preferred side of boiler  
(Fig 1)  
GeneralDetails
NameSchneider Drayton Digistat 3rd Generation Wireless Programmable Room Thermostat User Guide
MakeSchneider
LanguageEnglish