INSTALLER OPTIONS - continued  
Technical Data  
(Option 07) Sensor Fault Function  
In the event of a sensor fault, central heating output is  
reduced to 30% by turning heating ON for 3 minutes, then  
OFF for 7 minutes.  
Power supply  
230VAC +/-10%, 50Hz  
3(1)A at 24~230V/50Hz  
Switch type & rating  
Min. recommended  
current  
SPDT (voltage free contacts)  
10mA@24VAC (inductive)  
(Option 08) Application Type  
Select the central heating system energy type.  
Ambient temperature  
(receiver)  
Operating 0°C to 45°C  
Storage - 20°C to 65°C  
(Option 09) System Capability  
Ambient temperature  
(thermostat)  
Operating 0°C to 40°C  
Storage - 20°C to 65°C  
Ambient humidity  
(non condensing)  
(Option 13) Installer Settings Lock  
20% to 80%, 90% non-condensing  
When enabled, installers can lock the installer settings menu until  
a 3 digit code is entered. If the code is forgotten while device is  
locked, please call the Technical Helpline.  
Temperature range  
Rated impulse voltage  
Ball pressure test  
5°C to 30°C  
4KV  
(Option 20) Reset (Service Interval settings are NOT reset)  
Reset the Digistat to its original factory settings.  
75°C  
Disconnection means  
Automatic action  
1B  
Note that resetting the thermostat will lose the pairing with the  
receiver. The receiver will also need to be reset before attempting  
to pair again. To reset the receiver press the receiver button for 15  
100,000 cycles  
2402-2480 MHz  
433.92 MHz  
Operating Frequency  
Radio Frequency  
Max RF Power  
transmitted (Bluetooth)  
+10dBm  
(Si Option 01) Si Status  
Enable or disable Service Interval Mode.  
Pollution situation  
Protection level  
Degree 2  
IP30  
(Si Option 02) Si Type  
Select effect imposed on the heating when service is due.  
Wiring  
comply with IEE wiring regulations  
V = 3% using OpenTherm connection  
(Si Option 03) Service Due Date  
Set date when next service is due.  
Energy Class  
Relevant EC Directives:  
2014/53/EU (RED)  
2011/65/EU (RoHS)  
2012/19/EU (WEEE)  
(Si Option 04) Warning  
Select no. of days before service due date.  
(Si Option 05) Service Due Alarm  
Enable or disable the audible service due alarm.  
Standards:  
EN 60730-1  
EN 60730-2-7  
EN 60730-2-9  
ESTI EN 300 328  
ESTI EN 301 489  
EN IEC 63000  
(Si Option 06) Si Boost  
Enable or disable the Service Boost feature (5 boosts).  
(Si Option 07) Password Reset  
Change the 4 digit PIN. If you forget your Si password, please  
call the Technical Helpline.  
What is it  
Select between  
Default  
01 Partial Sight Assistant  
02 Frost Protection  
03 Low Set Point C  
OFF  
ON  
ON  
ON  
5
ON  
OFF  
5
High Limit  
04 High Set Point C  
05 Optimum Start  
Low Limit  
OFF  
30  
30  
Delayed Start  
Optimum Start  
4
OFF  
06 Valve Protection Time (Mins)  
07 Sensor Fault Function  
08 Application Type  
09 System Capability  
13 Installer Settings Lock  
20 Reset  
OFF  
5
3
2
1
OFF  
OFF  
ON  
OFF  
Gas  
Electric  
Oil  
Heat Pump  
Gas  
Fast Flow  
OFF  
Normal/Slow Flow  
Fast Flow  
OFF  
ON  
NO  
YES  
NO  
01 Si Status  
OFF  
ON  
OFF  
02 Si Type  
Reduced Comfort  
Heating OFF  
No Effect  
Reduced Comfort  
03 Si Due Date  
04 Si Warning  
05 Si Due Alarm  
06 Si Boost  
YY/MM/DD  
0
99  
30  
OFF  
ON  
ON  
OFF  
OFF  
0000  
OFF  
07 Si Password Reset  
Select 4-digit PIN  
GeneralDetails
NameSchneider Drayton Digistat 3rd Generation Wireless Programmable Room Thermostat User Guide
MakeSchneider
LanguageEnglish
FiletypePDF (Download)
File size0.36 MB
Download PDF