INSTALLER OPTIONS  
If your boiler supports OpenTherm please follow these  
instructions:  
To make changes to the default Installer Options shown below,  
enter the Installer Options menu by pressing the settings  
button for 3 seconds. This allows access to the User Menu  
01, the Advanced User Settings Menu 02, the Installer Settings  
03, and Service Interval Settings 04. Use the + and - buttons  
to scroll to Installer Options and press O to select. You can exit  
Remove the OpenTherm cables from the existingcontroller or  
thermostat. Connect the cables to the OpenTherm terminals  
OT1 and OT2 on the Receiver. Polarity is not important.  
Wire L and N from a separate supply with a 3A fuse.  
Note that when connected to an OpenTherm boiler, Installer  
Options 06 Valve Protection and 08 Application Type are not  
available. The following options will appear in the Installer  
Options list:  
the menu by pressing  
until you have returned to the home  
screen. In the Installer Options menu (Fig 8), scroll through the  
options using the + and - buttons and press O to select. Scroll  
through the different settings using the + and - buttons and  
press O to select and save. (Fig 9 shows Option 02 OFF).  
10 Upper CH water set point  
11 Lower CH water set point  
12Set DHWtemp  
30-80°C  
10-25°C  
45-70°C  
Default 70°C  
Default 10°C  
Default 60°C  
3. Replace the front cover of the receiver by locating the two  
latches at the top and then fasten the two screws at the  
bottom. As soon as the Digistat receiver has power it will be  
ready for automatic pairing with the Digistat RF Thermostat .  
(Fig 8)  
(Fig 9)  
(Option 01) Partial Sight Assistant  
Before pairing it is possible to test the wiring to the boiler by  
When enabled, audible tones indicate when the setpoint is  
more than, less than or equal to the current room  
temperature when a user manually adjusts the setpoint using  
the + button:  
hour or until the button is pressed again.  
Setpoint > room temperature - single high tone per 0.5°C  
increase  
Setpoint = room temperature - double tone  
Setpoint < room temperature - single low tone per 0.5°C  
decrease  
(Option 02) Frost Protection  
The Digistat will switch on the heating if the temperature  
falls to 5°C and maintains a temperature of 7°C even when  
in OFF mode.  
(Fig 4)  
4. Automatic pairing  
When the Digistat receiver is powered and the Digistat  
(Option 03) Minimum Setpoint Limit  
Change minimum setpoint temperature. After any changes to  
Thermostat has batteries inserted both will automatically pair.  
setpoint limits, all setpoints in AUTO, MANUAL, BOOST and  
green/amber and the thermostat will display the word SCAN.  
Once paired the receiver LED will be solid green and the  
thermostat display will show the words PAIR REC for 3 seconds,  
before displayingcurrent time and temperature.  
(Option 04) Maximum Setpoint Limit  
Change maximum setpoint temperature. After any changes to  
setpoint limits, all setpoints in AUTO, MANUAL, BOOST and  
Automatic pairing is turned off aꢀer 2 minutes. To pair  
manually follow the process below:  
(Option 05) Optimum Start  
1. Reset the Digistat using option rSET20 in the InST03 menu,  
then remove the batteries.  
When enabled, this uses current ambient temperature, the  
next scheduled setpoint and heat gain data captured by the  
device to adjust the thermostat setpoint early, so the ambient  
temperature is at the required level when the next event starts.  
2. Press and hold the Receiver button for 15 seconds until you  
see a red LED followed by flashing orange/green LED.  
3. Place the batteries in the Digistat and they will pair as above.  
Delayed Start  
When enabled, this uses current ambient temperature, current  
event setpoint and heating characteristics of the environment  
to delay implementation of the setpoint if the ambient  
temperature is already close to it, therefore saving energy.  
(Option 06) Valve Protection Time  
(Fig 5)  
(Fig 6)  
In some hydronic heating systems it may be required to  
protect the valve by operating it for a given time. When  
enabled, this maintenance feature ensures that each relay  
output is operated for at least one (1) minute each week.  
5. The Digistat is now installed and will automatically start to  
control room temperature.  
GeneralDetails
NameSchneider Drayton Digistat 3rd Generation Wireless Programmable Room Thermostat User Guide
MakeSchneider
LanguageEnglish
FiletypePDF (Download)
File size0.36 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Schneider SpaceLogic Thermostat Installation Guide
Schneider SpaceLogic Thermostat Installation Guide

Schneider Drayton Digistat 3rd Generation Wireless Programmable Room Thermostat User Guide