Home > GA Plumbing > GA Plumbing I8 Wi-Fi Underfloor Heating Thermostat User Manual

GA Plumbing I8 Wi-Fi Underfloor Heating Thermostat User Manual

I8 THERMOSTAT  
User Manual • Uživatelský manuál •  
Užívateľský manuál • Használati utasítás •  
Benutzerhandbuch  
GeneralDetails
NameGA Plumbing I8 Wi-Fi Underfloor Heating Thermostat User Manual
MakeGA Plumbing
LanguageEnglish
FiletypePDF (Download)
File size0.61 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

GA Plumbing I8 Wi-Fi Underfloor Heating Thermostat User Manual
Get the free PDF manual for the GA Plumbing I8 Wi-Fi Underfloor Heating Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GA Plumbing I8 Manual: Questions and Answers

GA Plumbing I8 specifications

Power supplyAC 95 ~ 230V 60Hz
Maximum load3A/16A
Setpoint range5~60°C
Accuracy±1°C
SensorNTC
Power consumption<1W

Full specifications, page 8

How do I install the GA Plumbing I8 thermostat in the electrical box?

Follow these steps to mount the thermostat.

  1. Connect the power supply box according to the wiring diagram.
  2. Push the panel up and take down the panel.
  3. Install the fixed plate of thermostat in electrical connection box with screws.
  4. Make the panel buckle to the fixed plate and push it down. User Manual, p. 6

What's the passive linkage output delay range on the GA Plumbing I8?

0-5 minutes. Adjust it in advanced options, menu item 8, using the up and down keys. User Manual, p. 8

GA Plumbing I8 compared with other floor heating thermostats

SpecificationGA Plumbing I8BEOK TDR89BHT BHT-001SeriesDEVI 140F1064
Power supplyAC 95 ~ 230V 60Hz100 ~ 240V95 ~ 240 VAC, 50 ~ 60HZ220-240 V~, 50/60 Hz
Setpoint range5~60°C5-95℃5 -35℃Room temperature: 5-35°C
SensorNTCNTCNTC3950, 10K±1%NTC 6.8 kOhm at 25°C