GA Plumbing I8 Wi-Fi Underfloor Heating Thermostat User Manual

Operating Instruction  
1. Power on/off: Long press M for 5 seconds on/off the thermostat.  
2. Press the M key to switch between manual and automatic modes.  
3. Long press M key and  
Settings Item, press  
key to enter the clock setting, press M key to switch  
and d key to adjust the value of each parameter. Note:  
the time of WIFI model will be automatically gets internet time.  
4. Press and for 5 seconds to add or cancel the child lock.  
5. WIFI link: When the thermostat is on, long press button for 5 seconds and the  
thermostat display will come out. Now the WIFI icon flashes, at this time the  
thermostat into the state of code.  
Advanced Options  
When POWER OFF, press the M key and the  
option setting.  
Press M to enter the next option, press  
height Level option.  
key for 5 seconds to enter the advanced  
and to adjust, and long press M to exit the  
The default value of the calibration room  
1
2
3
4
5
Temperature compensation  
Sensor selection  
temperature is -2°C. Press the up and down keys to  
adjust. The adjustable range is 9.9°C to -9.9°C.  
The temperature sensor is selected as IN by  
default. Press the up and down keys to adjust as IN  
respectively, indicating that the internal.  
The default temperature limit value is 35°C. Press  
Modify the temperature limit the up and down keys to adjust the range from 5°C  
to 60°C.  
The default temperature difference is set to 1°C.  
Temperature difference start Press the up and down keys to adjust the range to  
1-10 degrees.  
Set the default anti-freeze function to OFF, display  
OFF, press the up key to turn on anti-freeze and  
display ON.  
Antifreeze function  
Set the default rest day as double OFF. Press the  
up and down keys to adjust it to double OFF (1-5)  
single OFF (1-6), no OFF (1-7) and turn off week  
programming (OFF).  
Set the default main and auxiliary reversal to 0.  
Press the up and down keys to adjust 0 to turn off  
the main and auxiliary reversal. 01 means auxiliary  
reverse, 02 means auxiliary reverse, 03 means  
main and auxiliary reverse, shutdown and  
antifreeze is not on, stop output  
Holiday option and turn off  
weekly programming  
(apolegamic)  
6
7
Primary and secondary  
reverse selection  