SALUS iT500 Internet Thermostat Installation Guide
Program schedule for heating zone
Setting up the iT500 thermostat
After powering up iT500 for the first time the display will go through the following sequence.
Selecting your system configuration
Setting the time and date
When connected to the internet, the iT500 will set time and date automatically. However this can also be set
manually.
This menu should only be entered by the installer as changes can have a detrimental effect on your heating system.
You can easily set your schedule via iT500 Plus app
thermostat, please follow the instruction below.
If you want to set schedules directly by the iT500
1
2
3
4
At any time press
for return to the previous step or hold
for 5 seconds to return to the home screen.
2
3
1
In iT500 thermostat you can define 6 schedule programs per day. You can set different temperature level for each
program. While programming specific time interval you must be aware that you are about to set at what time the
program will start. For example, if you set program 1 for 6:00 (AM) it means the program is going to run at 6:00 (AM)
and will running till the time set for next program. Example of 4 temperature levels for 6 schedule programs:
2
3
1
OTA (Over The Air
operated software)
revision number
iT500 Software revision
The globe icon
will
P4
P5
P6
P2
22°C
9
appear when the unit
automatically connects to
the internet via the SALUS
iTG500 Gateway. This
should take approximately
20 seconds.
P3
P1
17°C
P1
17°C
23°C
23°C
23°C
19°C
Press and hold button.
Press again button
to change value.
Press
button to confirm.
0
1
2
3
4
5
6
7
8
10
11 12 13 14
15 16 17 18 19 20 21 22 23 24
Press the power button
to highlight the display.
Press and hold
Press
button to confirm.
5
6
4
Note: When you set program schedule, necessarily set all 6 programs. I.e. if you want to set 2
temperature levels, you need to set first temperature level for 1 to 5 program and set second
temperature level only for program 6.
and
buttons for 3 sec.
Press
or
button to select your system configuration. To confirm press
button.
2
3
1
Pairing iT500 with iT500RX receiver
4a
4b
4c
2
3
1
Press
to set 12 or 24 hour format.
Press button to confirm.
or
button
Press
or
to set the hour.
button to confirm.
button
Follow the same steps to set
the minutes, day, month
and year.
Press
+
+
Press the power button
to highlight the display.
Press the power button
to highlight the display.
Press and hold button
for 3 seconds.
onfirm.
One central heating zone.
Two central heating zones.
One central heating zone
+ hot water system
Operating modes
4
5
6
4
5b
5c
5a
Using a paper clip, insert into the The bottom switch will show
hole marked SYNC at the bottom a constant red light when iT500RX
of iT500RX receiver.
receiver is ready to pair.
Now go to iT500 thermostat.
Press and hold and
buttons for 3 sec.
utton to select
temperature zone.*
*(only in two heating zones)
tton to confirm.
Press
ALL, 5/2 or INDIVIDUAL days.
Press button to confirm.
button to choose
- automatic mode
(works according to the schedule)
Permanent manual mode
- antifrost mode 5°C
(changing temperature is avaible
only through the app)
or
or
or
6
7
5
1
8
9
7
3
4
Press the power button
to highlight the display.
Press
button to launch
pairing process.
Pairing process can take
up to 10 minutes.
Press
or
button to select heating or cooling* mode. Press
*Cooling can only be selected if your system supports this.
button to confirm.
2
Press
to set start hour for program 1.
or
button
Press
to set start minutes for program 1.
Press button to confirm.
or
button
Press
to set temperature level for
program 1. Press button
to confirm. Follow the steps 7-9
to set next programs.
or
button
When iT500RX receiver
and iT500 thermostat are paired
then the light will be green.
FAILSAFE MODE: In the event of RF signal loss, your system will
be switched on for 4 minutes, then off for 11 minutes. If you want to
disable FAILSAFE MODE when RF link has been lost then move the
slide switch on iT500RX to either the Manual or Off position.
Press
button to confirm.
6
7
Press and hold and
buttons for 3 sec.
Press
to select operating mode.
Press button to confirm.
or
Press
or to return
to the home screen.
utton to select
temperature zone or HW.*
*(only in two heating zones or one heating
Program schedule for hot water system
Pairing the iT300 to the thermostat
zone + hot water system)
2
3
1
Press
to select temperature unit.
or
button
Press
or
button
Note: iT300 purchased separately. Can only be used if your system supports second central heating zone.
to select time zone (GMT).
Press button to confirm.
Setting the temperature
Press
button to confirm.
GMT+1 Hour
2 3
1
Note: If you set the temperature in AUTO mode (temporary override) the setpoint temperature won’t be
changed until the next program starts.
GMT
GMT+2 Hour
GMT+3 Hour
3a
Press the power button
to highlight the display.
Press and hold button
for 3 seconds.
ress
button to confirm.
Press the power button
to highlight the display.
5
6
4
UK
IRELAND
AUSTRIA
BELGIUM
DENMARK
SWEDEN
NORWAY
MALTA
ESTONIA
TURKEY
CYPRUS
GREECE
BULGARIA
LITHUANIA
BELARUS*
FINLAND
MOLDOVA
LATVIA
RUSSIA*
4
POLAND
GERMANY
CZECH
2
1
PORTUGAL
ICELAND*
Press
to change temperature.
Press button to confirm.
or
button
SPAIN
FRANCE
ITALY
ROMANIA
RUSSIA
UKRAINE
To pair iT300 to the receiver, insert
A red light will flash in the top
right hand corner of the iT300.
CROATIA
SERBIA
a paperclip or similar object into
the hole on the left hand side
of iT300 for 2 seconds.
SWITZERLAND BOSNIA
LUXEMBOURG SLOVENIA
utton to select
hot water system
Press
button to confirm.
Press
ALL, 5/2 or INDIVIDUAL days.
Press button to confirm.
button to choose
3b
Press and hold and
buttons for 3 sec.
.
HOLLAND
SLOVAKIA
Press button to select
temperature zone or HW.*
*(only in two heating zones or one heating
Press the power button
to highlight the display.
6
7
5
The countries marked with * do not observe Daylight Saving Time. For details please see below.
zone + hot water system)
8
9
7
8
Set hour value of boosting your
hot water by pressing
You can cancel temporary override by holding
button
DST (Daylight Saving Time) ON will automatically change your time
from summer to winter.
or
button.
button to confirm.
for 3 seconds. Setting indicator should disappear.
Press
Press
button to launch
pairing process.
Pairing process can take
up to 10 minutes.
iT500 has successfully paired with
iT300 when the antenna stops
flashing.
Press
to set start minutes for program 1.
Press button to confirm.
or
button
Set time for turn OFF program 1
cognately to step 7-8.
Press
or
button
to set start hour for program 1.
Press button to confirm.
Press
or
to the home screen.
to return
Lock Function
Press
button to confirm.
Press
or
button
The iT300 should be installed
in the area of the house that
the second zone will be
controlled from, ie. Upstairs.
Follow the steps 7-9 to set
next programs.
To enable or disable lock function press and hold
together.
and
buttons
to turn ON or OFF day saving
time function.
Press
Please note the red LED
on the iT300 will continue to
flash and eventually timeout.
button to confirm.
Note: In program schedule for hot water system (HW) you can set 3 schedule programs per day.
For each HW program you must define the time of start and the time of the end.
| General | Details |
|---|---|
| Name | SALUS iT500 Internet Thermostat Installation Guide |
| Make | SALUS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.49 MB |

SALUS IT800 WIFI Smart Thermostat Installation Guide

SALUS 091FLRF Wireless Room Thermostat User Guide

SALUS Thermostat Sensor TS600 User Guide

SALUS Thermostat and Smart Plug Installation Guide

SALUS Programmable Wired Thermostat VS30W/VS30B Installation Guide

SALUS Wired Thermostat Installation Guide

SALUS Wired Digital Thermostat – Non-programmable HTRS230 User Manual

SALUS RT520 Radiator Thermostat User Guide

SALUS RT310 Thermostat User Manual

SALUS Thermostat RT520 User Manual