PowerOptimal Elon Smart Thermostat User Guide

Elon® Smart Troubleshooting  
Guide for Electricians V1.4  
ID  
11  
12  
Alarm message  
How to resolve the alarm  
DC Wired to AC Input  
No Power on DC Input  
Wire DC to correct input (see Chapter 4).  
This can be due to several reasons:  
a. There is no DC power connected to the Elon Smart  
b. DC power is off at the DC disconnect switch close by  
the Elon Smart unit.  
c. There is an issue with the DC wiring or solar PV  
installation.  
d. It is extremely dark and overcast during daytime. (The  
alarm is not active when the sun is less than 15 degrees  
above the horizon.)  
This alarm won’t prevent the Elon Smart unit from  
functioning and heating water with grid (AC) power as  
long as there is grid power available.  
You can clear the alarm by switching the DC power on  
(where applicable), fixing the DC wiring / solar PV  
installation, setting the Elon Smart heating policy to Grid  
Only (see Table 4.1) or you can leave it until DC power  
returns.  
13  
14  
DC Input Reversed  
Hot Connection  
The wiring on the Solar input has been installed  
incorrectly (in reverse). The DC+ (positive) wire has been  
connected to the DC- (negative) terminal on the Elon  
Smart and the DC- (negative) wire has been connected to  
the DC+ (positive) terminal on the Elon Smart. Swap the  
DC wires around (see Chapter 4).  
Elon Smart not correctly inserted into geyser element.  
Switch off all power to the Elon Smart and re-seat  
(reinsert) the Elon Smart.  