TECHNICAL SPECIFICATIONS
Purpose of control
Electrical underfloor heating
Wall mounting in a socket or
mounting box
Method of mounting.
Supply voltage
Max. pre-fuse
100-240 VAC 10% 50/60 Hz
16 A
Built-in interupter
Enclosure rating
2-pole, 16 A
IP 21
Current ≤ 13 A - 1.5 mm2, solid core
wire
Wire size, terminals
Current > 13 A to 16 A - 2.5 mm2,
solid core wire
ELV limits realized
Output relay
SELV 24 VDC
Make contact - SPST - NO
Output, load
Max. 16 A / 3600 W
Control principle
Standby consumption
Battery backup
PWM/PI
≤0.5 W
5 years (storage)
Battery life, typical
Dimensions
5 years (storage) 10 years (powered)
MxD5: H/84, W/84, D/40 mm
Build-in depth
22mm
Weight
≤200 g
Display
176x220 pixels TFT - resistive touch
Control pollution degree
Overvoltage category
Type of action
2
III
1.B
Software class
A
Rated impulse voltage
Ball pressure temperature (TB)
EU registered design
4kV
125°C
DM/082270
Note: At very low ambient temperatues the display may respond slowly.
© 2021 OJ Electronics A/S
13
| General | Details |
|---|---|
| Name | OJ ELECTRONICS MCD5 Touch Thermostat Instructions |
| Make | OJ Electronics |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.19 MB |

OJ ELECTRONICS UTN5 OJ Microline Non Programmable Thermostat User Manual

OJ ELECTRONICS UTN5 Non Programmable Touch Thermostat Instruction Manual

OJ ELECTRONICS UDG-4999 Thermostat with Class A GFCI Owner’s Manual

OJ ELECTRONICS MWD5-1999-UAC3 Voice Control Wi-Fi Thermostat Instructions

OJ ELECTRONICS MWD5-1999-R3C3 Voice Thermostat Instructions

OJ ELECTRONICS MCD3 Digital Thermostat Instructions

OJ ELECTRONICS UTN-4991 Non Programmable Thermostat Owner’s Manual