nVent RAYCHEM GM-TA Thermostat Instruction Manual
Installation
The GM-TA thermostat is intended for installation
EN
DE within a distribution panel. The thermostat is to
be powered from a 230 Vac electrical supply in
FR
SV
accordance with local electrical regulations. The
heating cable and earthing connections need to be
made in accordance with the circuit wiring diagram
(figure C - last page).
Outdoor installaton of the GM-TA thermostat is
possible by using the nVent GM-TA-OUTDOOR-BOX
(PCN 1244-017966) with IP65 rating.
The GM-TA-AS sensor must be installed outside the
building and securely fastened to the wall (preferably
north facing) (figure B). The sensor must be connected
with a sensor cable (e.g. round 3 x 1,5 mm², max.
100 m) to the GM-TA thermostat.
Display
A-LED Display (temperature and alarm)
-Off: Heating cable OFF
0
-On: Heating cable ON
0
A
-Blinking: Post heating or Test
1-Program mode selection ON /OFF
2-Reduce value (change set temperatures)
3-Increase value (change of set
temperature)
4
|
nVent.com/RAYCHEM
| General | Details |
|---|---|
| Name | nVent RAYCHEM GM-TA Thermostat Instruction Manual |
| Make | nVent RAYCHEM |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.31 MB |

nVent RAYCHEM ETS-05 Electronic Thermostat Instruction Manual

nVent RAYCHEM RAYSTAT-EX-02 Mechanical Thermostat Installation Guide

nVent RAYCHEM Elexant 3500i Electronic Thermostat Installation Guide

nVent RAYCHEM RayStat-M2 Thermostat Instruction Manual

nVent RAYCHEM Green Leaf Programmable Thermostat Instruction Manual

nVent RAYCHEM AT-TS-13 Surface Sensing Thermostat Instruction Manual

nVent RAYCHEM SENZ Wifi Programmable Floor Heating Thermostat User Guide