Product overview  
nVent RAYCHEM AT-TS thermostats provide temperature control in non-hazardous area.  
The temperature set point can be checked through a window in the lid. LED’s are providing  
an indication when the relay contact is closed (Heating ON) and when the temperature  
sensor is defect (sensor break or sensor short-circuit).  
The temperature sensor has a length of 3 meter and can be shortened for ambient sensing  
operating. Direct connection of the heating cable is possible. Connection kits need to be  
ordered separately. The thermostat is available in 2 temperature ranges.  
Functional description  
When the temperature exceeds the setpoint, the switching contact opens and switches the  
heating cable off.  
When the temperature falls below the setpoint, the switching contact closes. The integrated  
green LED display lights up to indicate that the heating cable is switched on. In the event of  
a sensor defect, the switching contact closes. The integrated red LED display lights up to  
indicate that there is a defect. In the event of power loss, the switching contact opens.  
Installation  
A. Pipe line sensing control  
1. Attach temperature sensor to the pipe with adhesive tape. The sensor should rest  
firmly against the pipe without intermediate space. The minimum distance of the  
sensor from fittings and the pipe end is 1 m. The angle of the pipe between the heating  
cable and the sensor should be 90-120°.  
2. Mount the housing in the required position.  
3. Adjust the temperature setpoint. Finish the wiring and insulation. Only operate with  
insulated sensor.  
4. Fill the pipes, check the operating points with a thermometer and correct if necessary.  
Due to the low heat conductivity of non-metallic pipes, adjust the thermostat operating  
point only when the pipe is full.  
nVent.com/RAYCHEM  
|
3
GeneralDetails
NamenVent RAYCHEM AT-TS-13 Surface Sensing Thermostat Instruction Manual
MakenVent RAYCHEM
LanguageEnglish
FiletypePDF (Download)
File size0.19 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
nVent RAYCHEM ETS-05 Electronic Thermostat Instruction Manual
nVent RAYCHEM ETS-05 Electronic Thermostat Instruction Manual
nVent RAYCHEM RAYSTAT-EX-02 Mechanical Thermostat Installation Guide
nVent RAYCHEM RAYSTAT-EX-02 Mechanical Thermostat Installation Guide
nVent RAYCHEM Elexant 3500i Electronic Thermostat Installation Guide
nVent RAYCHEM Elexant 3500i Electronic Thermostat Installation Guide
nVent RAYCHEM RayStat-M2 Thermostat Instruction Manual
nVent RAYCHEM RayStat-M2 Thermostat Instruction Manual
nVent RAYCHEM Green Leaf Programmable Thermostat Instruction Manual
nVent RAYCHEM Green Leaf Programmable Thermostat Instruction Manual
nVent RAYCHEM SENZ Wifi Programmable Floor Heating Thermostat User Guide
nVent RAYCHEM SENZ Wifi Programmable Floor Heating Thermostat User Guide
nVent RAYCHEM GM-TA Thermostat Instruction Manual
nVent RAYCHEM GM-TA Thermostat Instruction Manual

nVent RAYCHEM AT-TS-13 Surface Sensing Thermostat Instruction Manual