Left button:
Push right button in main screen to go straight to Menu settings (2.4)
Confirming a choice
Select an option
(
)
Right button:
Push left button in main screen to go straight to Mode functions (2.3)
To get back to last screen or main screen(← or X )
USERMANUAL
Always go back to the main screen after making changes.
Explanation of LED colours / signals :
Heating
Red:
System operation(standard or Costum)
Green:
Installation
Red light flashing on and off: Sensor fault
1.Check if the power is off. Remove the display frame by pushing a non sharp
instrument (for example the point of a ballpoint pen) carefully in the square hole
underneath the thermostat.
2.Connection schedule:
L/N lead : Connect the power cord using the terminal block.
L1/N1 lead : Use a terminal block to connect the load line(Max 16A).
S1/COM/ : Connect the floor sensor.
Date
Time
Pilot : Connect the pilot to L when the pilot wire function needs to be enabled.
WARNINGS: 1.Disconnect the main power supply before wiring.
Installation needs to be done by a qualified electrician in accordance with
all current wiring and building regulations. 2.Electric floor heating cable/
mat must be in accordance with the supply voltage. The terminals are
designed to handle a cross-section of wire measuring 12-22AWG.
Measured Temp
Mode
Menu
Menu/Confirm
LED
Mode/get back
3.The display frame and the cover frame can be removed. Position the
thermostat and install onto the back box (not supplied). Place the display frame
back into position by pushing it softly.
Up/Down/Scroll
POWER
Start up wizard
L
a
n
g
u
a
g
e
Date
1
2
Units
3
-year;
program the current year.
-make your language choice.
This is the first question in the
start up menu.
- Clock;
choose 12 or 24 hour clock
time (am/pm) .
01
02
-month;
program the current month.
- Temperature;
choose °C or °F scale .
-day number;
program the current day.
Time
Intelligence
Heating system
4
5
6
-program time;
program the actual clock time
-This function enables the
thermostat to calculate when
it needs to switch on so that
the required temperature is
reached at the set time.
-Floor heating or different
heating system. If you choose
a different heating system the
question will be whether the
system needs to function on
the internal room sensor or
external sensor.
04
03
Note:
According to user preference,
the circular and square outer
frame can be replaced.
Summary
Surface material
Temp.to control
9
7
8
-If you choose floor heating.
Wood or other. If you choose
other, the question is asked if
there is a floor sensor installed
-Containing the current
settings.
-Floor or room sensor.
05
If you choose floor heating,
we advise you to control the
floor temperature by using
the floor sensor.
Supply voltage:
Load:
85-265 VAC 50/60 Hz
max.16 A (resistive load)
11 Overview wizard
Slow heating
Temperature
12
10
-Containing the selected
heating periods according the
standard program.
-It is possible to choose this
option (Ref Mode selection
point 7 slow start up).
-Program the comfort temp-
erature of your choice for a
heating period. Standard
temperature for a “different
heating system is program-
med at 21 degree Celsius and
23 degree Celcius for a floor
heating system.
Setpoint range:
Temperature range:
Cover:
+5 to +40°C / +41 to +104°F
+5 to +45°C / +41 to +113°F
IP21
Approvals:
CE/UKCA
Floor sensor type:
NTC B=3740 12k
Operation and LED
Keys operation:
←
Mode selection
1.Automatic mode:
Middle buttons:
Adjustment up and down (±o
To scroll through settings
)
According to the weekly program, the thermostat automatically adjusts the
set temperature operation.
| General | Details |
|---|---|
| Name | Klima 825200 Electric Underfloor Heating Thermostat User Manual |
| Make | klima |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.35 MB |

Klima 825201 Intelligent Control Wi-Fi Underfloor Heating Thermostat User Manual

klima SF300 Thermostat User Manual

Klima C16 WiFi Floor Heating Thermostat User Guide

Klima H001 Smart Thermostat For Air Conditioner User Manual

Klima SF300 Digital Thermostat Instruction Manual

Klima 825200 Electric Underfloor Heating Thermostat User Manual Overview
Summary of Contents
- Page 1: Left button allows access to menu settings. Right button provides quick access to mode functions. Always return to the main screen after making changes. Red LED indicates system operation, while green indicates installation. Flashing red light signals a sensor fault. Disconnect the main power supply before wiring. Installation must be performed by a qualified electrician. The thermostat can be configured for different heating systems. The startup wizard allows programming of date, time, and temperature units. The thermostat automatically adjusts temperature based on the weekly program.
- Page 2: Settings: Temporary temperature allows changes related to thermostat operation. Date and time: The thermostat automatically adjusts for summer and winter clock changes. Manual mode: The thermostat runs continuously according to the set temperature. Anti-frost mode: Keeps the room at a lower temperature when on vacation. Heating system: Type of heating system and surface material can be selected. Timer: Settings can be adjusted using the startup wizard. Slow heating: The thermostat gradually raises the floor temperature over 20 days. Open window: The thermostat shuts off automatically for 15 minutes when a window opens. Child lock: Locks the thermostat settings to prevent changes. Information: Displays the current software and hardware version of the thermostat.