Klima SF300 Digital Thermostat Instruction Manual
4. Time setting
• (Thermostat on) Long press o to enter options
• Press▲, choose 01 and press o to enter
• Press▼or▲to set minutes
SF300 Digital thermostat
Operating instructions
• Press o to confirm and enter hour setting
• Press▼or▲to set hours
Read this manual carefully and keep it with other warranty do-
cuments. Connection must be carried out by a qualified installer
in accordance with local regulations. Before installing or disas-
sembling the thermostat, always switch off the electricity in the
meter cupboard. This thermostat can be installed in a single flush-
mounting box 50 mm deep, according to standard DIN formats.
• Press o to confirm
• Press▼or▲to set week day (Monday = 1, Sunday = 7)
• Press o to confirm
5. Choose mode
Press o to switch between Auto Mode or Manual mode.
6. Programming (Auto Mode)
(Thermostat on) Long press o to enter options
press▲, choose 02 and then o to enter programming
Press o to choose hours, min. and temp. (with▼or▲and o)
There are 3 periods (6 setpoints) per day. See standard scedule
for reference:
On/Off Mode (o)
- key
+ key
Wake up
(On)
Away
(Off)
Home
(On)
Away
(Off)
Home
(On)
Sleep
(Off)
Setpoint 1 Setpoint 2 Setpoint 3 Setpoint 4 Setpoint 5 Setpoint 6
1. Technical details
06:00 20oC 08:00 15oC 11:30 20oC 13:30 15oC 17:00 20oC 22:00 15oC
Power
90-240Vac 60/60Hz
16A/250V
Max. Load
Floor sensor type 10k NTC 1%
Temp. range
Accuracy
Cover
5oC-35oC
0.5oC
IP21
7. Holiday Mode
• (Thermostat on) Long press o to enter options
• Press▲, choose 03 and press o to enter
• Press▼or▲to set days
Warranty
2 years
• Press o to confirm and enter temperature setting
• Press▼or▲to set temperature
• Press o to confirm
2. Wiring diagram
1
2
3
4
5
Power supply (Line)
Power supply (Neutral)
Heating cable wire 1*
Heating cable wire 2*
N/A
8. Sensor error
When an “E1” or “E2” code is shown the sensor is wrongly con-
nected or broken. The thermostat will stop heating until the sensor
is connected correctly or replaced.
6-7 Floor sensor connection
* Order Heating wire 1 and 2 does not apply.
EARTH: Connect the earth of the heating cable and the earth of
the power supply outside the thermostat.
9. Advanced settings
WARNING: Changing advanced settings may cause undesired results.
Please consult your installer before entering this menu!
3. Display icon explainantion
Press the on/off button once, long press o to enter Advanced menu A.
Press o to choose between A1 to AE. Press▼or▲to adjust.
Both Auto and Manual indicators on:
Temporary temp. is manually set in Auto Mode.
Returns to auto program schedule at next setpoint.
No. Item
Parameters
Default
A1 Measured temp. calibration -9oC to +9oC 0.5oC
Auto
mode
(point 5)
Manual
mode
Holiday
mode
(point 6)
Heating
active
Day
indicator
(point 4)
A2 Differential 0.5oC to 2.5oC 1oC
A3 Key lock 0: Half lock 0
1: Full lock
A4 Power with memory function 0: Power with memory function 0
1: Shutdown power after power off
2: Shutdown power after power on
A5 Backlight time 5 to 30 seconds 10 sec
A6 Programmable 0: 5+2 (Week 1-5 and weekend 6-7) 0
1: 6+1 (Week 1-6 and sunday 7)
2: 7 (Week 1-7)
Temp.
A7 Lowest temp. setting 1 - 10oC 5oC
A8 Highest temp.setting 20-70oC 35oC
reading
A9 Low temp.protection 1: 1oC - 10oC 5oC
Function off: > 10oC Display (-----)
AA High temp.protection 1: 35oC-70oC 45oC
2: Function off: < 35oC Display (-----)
AB High temp. protection 1-9 2
differential
Frost
protection
active
Open
window
active
Key lock
active
Current
period
indicator
AC Running temp. of open 1: 10 - 20oC, 15oC
window function 2: Function off: < 10oC Display (-----)
Time
(point 4)
AD Running time of open window 10 - 20 min 10
function
AE Reset to factory settings Long press o until display goes blank -
Long press ▼to lock or unlock.
| General | Details |
|---|---|
| Name | Klima SF300 Digital Thermostat Instruction Manual |
| Make | klima |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.13 MB |

Klima 825201 Intelligent Control Wi-Fi Underfloor Heating Thermostat User Manual

klima SF300 Thermostat User Manual

Klima 825200 Electric Underfloor Heating Thermostat User Manual

Klima C16 WiFi Floor Heating Thermostat User Guide

Klima H001 Smart Thermostat For Air Conditioner User Manual

Klima SF300 Digital Thermostat Instruction Manual Overview
Summary of Contents
- Page 1: Time setting Press to enter options. Choose and press to enter. Set minutes and confirm. Set hours and confirm. Set week day and confirm. Choose mode Switch between Auto Mode or Manual mode. Programming (Auto Mode) Choose hours, minutes, and temperature. There are 3 periods (6 setpoints) per day. Sensor error When an “E1” or “E2” code is shown, the sensor is wrongly connected or broken. Advanced settings Changing advanced settings may cause undesired results. Display icon explanation Press the on/off button to enter Advanced menu A.