Home > klima > Klima SF300 Digital Thermostat Instruction Manual

Klima SF300 Digital Thermostat Instruction Manual

4. Time setting  
• (Thermostat on) Long press o to enter options  
• Press, choose 01 and press o to enter  
• Pressorto set minutes  
SF300 Digital thermostat  
Operating instructions  
• Press o to confirm and enter hour setting  
• Pressorto set hours  
Read this manual carefully and keep it with other warranty do-  
cuments. Connection must be carried out by a qualified installer  
in accordance with local regulations. Before installing or disas-  
sembling the thermostat, always switch off the electricity in the  
meter cupboard. This thermostat can be installed in a single flush-  
mounting box 50 mm deep, according to standard DIN formats.  
• Press o to confirm  
• Pressorto set week day (Monday = 1, Sunday = 7)  
• Press o to confirm  
5. Choose mode  
Press o to switch between Auto Mode or Manual mode.  
6. Programming (Auto Mode)  
(Thermostat on) Long press o to enter options  
press▲, choose 02 and then o to enter programming  
Press o to choose hours, min. and temp. (withorand o)  
There are 3 periods (6 setpoints) per day. See standard scedule  
for reference:  
On/Off Mode (o)  
- key  
+ key  
Wake up  
(On)  
Away  
(Off)  
Home  
(On)  
Away  
(Off)  
Home  
(On)  
Sleep  
(Off)  
Setpoint 1 Setpoint 2 Setpoint 3 Setpoint 4 Setpoint 5 Setpoint 6  
1. Technical details  
06:00 20oC 08:00 15oC 11:30 20oC 13:30 15oC 17:00 20oC 22:00 15oC  
Power  
90-240Vac 60/60Hz  
16A/250V  
Max. Load  
Floor sensor type 10k NTC 1%  
Temp. range  
Accuracy  
Cover  
5oC-35oC  
0.5oC  
IP21  
7. Holiday Mode  
• (Thermostat on) Long press o to enter options  
• Press, choose 03 and press o to enter  
• Pressorto set days  
Warranty  
2 years  
• Press o to confirm and enter temperature setting  
• Pressorto set temperature  
• Press o to confirm  
2. Wiring diagram  
1
2
3
4
5
Power supply (Line)  
Power supply (Neutral)  
Heating cable wire 1*  
Heating cable wire 2*  
N/A  
8. Sensor error  
When an “E1” or “E2” code is shown the sensor is wrongly con-  
nected or broken. The thermostat will stop heating until the sensor  
is connected correctly or replaced.  
6-7 Floor sensor connection  
* Order Heating wire 1 and 2 does not apply.  
EARTH: Connect the earth of the heating cable and the earth of  
the power supply outside the thermostat.  
9. Advanced settings  
WARNING: Changing advanced settings may cause undesired results.  
Please consult your installer before entering this menu!  
3. Display icon explainantion  
Press the on/off button once, long press o to enter Advanced menu A.  
Press o to choose between A1 to AE. Pressorto adjust.  
Both Auto and Manual indicators on:  
Temporary temp. is manually set in Auto Mode.  
Returns to auto program schedule at next setpoint.  
No. Item  
Parameters  
Default  
A1 Measured temp. calibration -9oC to +9oC 0.5oC  
Auto  
mode  
(point 5)  
Manual  
mode  
Holiday  
mode  
(point 6)  
Heating  
active  
Day  
indicator  
(point 4)  
A2 Differential 0.5oC to 2.5oC 1oC  
A3 Key lock 0: Half lock 0  
1: Full lock  
A4 Power with memory function 0: Power with memory function 0  
1: Shutdown power after power off  
2: Shutdown power after power on  
A5 Backlight time 5 to 30 seconds 10 sec  
A6 Programmable 0: 5+2 (Week 1-5 and weekend 6-7) 0  
1: 6+1 (Week 1-6 and sunday 7)  
2: 7 (Week 1-7)  
Temp.  
A7 Lowest temp. setting 1 - 10oC 5oC  
A8 Highest temp.setting 20-70oC 35oC  
reading  
A9 Low temp.protection 1: 1oC - 10oC 5oC  
Function off: > 10oC Display (-----)  
AA High temp.protection 1: 35oC-70oC 45oC  
2: Function off: < 35oC Display (-----)  
AB High temp. protection 1-9 2  
differential  
Frost  
protection  
active  
Open  
window  
active  
Key lock  
active  
Current  
period  
indicator  
AC Running temp. of open 1: 10 - 20oC, 15oC  
window function 2: Function off: < 10oC Display (-----)  
Time  
(point 4)  
AD Running time of open window 10 - 20 min 10  
function  
AE Reset to factory settings Long press o until display goes blank -  
Long press to lock or unlock.  
GeneralDetails
NameKlima SF300 Digital Thermostat Instruction Manual
Makeklima
LanguageEnglish
FiletypePDF (Download)
File size0.13 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Klima 825201 Intelligent Control Wi-Fi Underfloor Heating Thermostat User Manual
Klima 825201 Intelligent Control Wi-Fi Underfloor Heating Thermostat User Manual
klima SF300 Thermostat User Manual
klima SF300 Thermostat User Manual
Klima 825200 Electric Underfloor Heating Thermostat User Manual
Klima 825200 Electric Underfloor Heating Thermostat User Manual
Klima C16 WiFi Floor Heating Thermostat User Guide
Klima C16 WiFi Floor Heating Thermostat User Guide
Klima H001 Smart Thermostat For Air Conditioner User Manual
Klima H001 Smart Thermostat For Air Conditioner User Manual

Klima SF300 Digital Thermostat Instruction Manual
Get the free PDF manual for the Klima SF300 Digital Thermostat Instruction Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Klima SF300 Digital Thermostat Instruction Manual Overview

Summary of Contents

  • Page 1: Time setting Press to enter options. Choose and press to enter. Set minutes and confirm. Set hours and confirm. Set week day and confirm. Choose mode Switch between Auto Mode or Manual mode. Programming (Auto Mode) Choose hours, minutes, and temperature. There are 3 periods (6 setpoints) per day. Sensor error When an “E1” or “E2” code is shown, the sensor is wrongly connected or broken. Advanced settings Changing advanced settings may cause undesired results. Display icon explanation Press the on/off button to enter Advanced menu A.