ENTERING THE ADVANCED INSTALLER SETTINGS MENU  
ADVANCED INSTALLER SETTINGS MENU  
The T-32-P2 contains factory defaults for all Advanced  
Installer Settings. Depending upon the user and  
equipment application, some settings may need to be  
changed.  
Symbol Default  
Function  
ST S8  
OF  
Leave at factory default  
SC SC  
OF  
Leave at factory default  
To enter the Advanced Installer Settings menu, push the  
O/RIDE button once then hold it down (15 seconds) until  
the number “88:15” is displayed on the LCD. Using the  
( ) ( ) arrow button, adjust the value until it reads  
“88:32” and then press the O/RIDE button to enter the  
menu. You can move forward or backwards through the  
menu by pressing the O/RIDE or PROG buttons.  
FO=2 - In programmable mode  
(Sw6=ON), fan runs continuously with  
program 1 through 4 and then in AUTO  
from program 4 - 1.  
ADVANCED INSTALLER SETTINGS MENU  
FO=3 - In programmable mode  
(Sw6=ON), fan control is a combination  
of option 1 and 2.  
Symbol Default  
Function  
PN 88  
32  
Keyboard Lock PIN. This is the required  
PIN for future entry into the Advanced  
Installer Setup menu. (Range 00-99)  
Fan Purge  
FP FP  
0
Adjustable from 0 - 5 minutes after  
heating or cooling cycle.  
LC LC  
00  
Keyboard Lock OFF  
FN 88  
A
Mode - Heat / Cool system.  
Programmable Mode  
LC=01 - All buttons are locked except  
( ) ( ) buttons.  
LC=02 - All buttons are locked except  
O/RIDE and( ) ( ) buttons.  
FN=C - Cooling only system.  
FN=H - Heating only system.  
LC=03 - All buttons are locked except  
MODE, O/RIDE and ( ) ( ) buttons.  
LC=04 - All buttons are locked except  
H3 H3  
AL  
H3=AL - W2 relay used for auxiliary and  
emergency heat.  
(Sw1 = OFF) (Sw2 = ON)  
MODE and ( ) ( ) buttons.  
LC=05 - All buttons are locked except  
O/RIDE button.  
H3=EH - W2 relay controls emergency  
heat.  
H3=AH - Do not use this function.  
H3=FF - Fossil Fuel (Y is locked out  
when W2 is energized.  
H3 = OF - W2 relay only operates as  
auxiliary heat in heat pump mode.  
LC=06 - All buttons are locked.  
LC=00 - Keyboard lock OFF.  
LC=01 - All buttons are locked except  
MODE button.  
LC=02 - All buttons are locked except  
MODE and ( ) ( ) buttons.  
LC=03 - FAN, and PROG are locked.  
MODE button can only select Auto or  
Manual Mode  
(Sw6=OFF)  
For NO remote sensor OR 1 or more  
remote indoor sensor without the  
onboard sensor being used.  
TT 88  
RS  
OFF.  
TT=OA - For outdoor remote sensor  
connection.  
LC-04 - MODE button can only select  
Auto or OFF.  
LC-05 - All buttons are locked.  
LC-06 - Same function as LC-05.  
TT=DA - Sends measured temperature  
from remote sensor via modbus but  
does not display the value on the LCD.  
TT=OC - For connecting dry contact  
switch.  
HL HL  
90  
50  
Maximum Heating or High Temperature  
Limit.(Adjustable from 41° F - 120° F)  
(Replaces user setpoints with  
pre-programmed cooling ‘OC’ and  
heating ‘OH’ setpoints)  
CL CL  
Minimum Cooling or Low Temperature  
Limit. (Adjustable from 43° F - 122° F)  
TT=OF - For connecting dry contact  
switch.  
CF CF  
F
Temperature Display  
(Degrees F or C)  
(Turns thermostat off when closed)  
TT=AV - For averaging BOTH the  
C1 CI  
0.0  
Internal Sensor Calibration  
(Adjustable +/- 9° F)  
sensor and remote  
internal thermostat  
indoor sensor(s) together.  
AF AF  
1
Freeze protection ON. If thermostat is  
OFF, heating will come on if room  
temperature falls below 41° F.  
Time Format  
(12 or 24 Hour Clock)  
TC 8C  
12  
0
TD 88  
Temperature Display  
AF=0 - No freeze protection.  
TD=0 - Displays set and space  
temperatures.  
TD=1 - Displays only the set  
OH 8H  
OF  
OF  
Override Heating Setpoint.  
(Adjustable from 41° F - 120° F)  
temperature.  
AH AH  
2.0  
After Hours Override Timer  
OC 8C  
Override Cooling Setpoint.  
(Adjustable from 43° F - 122° F)  
Temporary Program Override 0 (OFF)  
extends override to next program  
change. 1 - 12 equals fixed hours of  
override.  
4 Schedules  
(Sw6=ON)  
(Sw8=ON)  
7
GeneralDetails
NameiO HVAC Controls T-32-P2 Universal Thermostat Instruction Manual
MakeiO HVAC Controls
LanguageEnglish
FiletypePDF (Download)
File size0.36 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
iO HVAC Controls UT32 Titan 3H or 2C Touchscreen Thermostat Owner’s Manual
iO HVAC Controls UT32 Titan 3H or 2C Touchscreen Thermostat Owner’s Manual
iO HVAC CONTROLS Z-2000-T Thermostat Instruction Manual
iO HVAC CONTROLS Z-2000-T Thermostat Instruction Manual

iO HVAC Controls T-32-P2 Universal Thermostat Instruction Manual